Maintenance

Structure of this document

Illustrations for this chapter are shown at 
the end of this document. References to the 
corresponding illustration sequences are 
shown as follows:

Maintenance interval

The following maintenance work is required 
as necessary or at the specified intervals at 
the latest:

Activating cleaning mode

Activate cleaning mode with the Geberit 
Service Handy or the Geberit Clean Handy. 
To clean the urinal ceramic and the cover 
plate, suppress the flush actuation for a few 
minutes.

Cleaning

Clean the cover plate and sensor window 
with a mild, liquid cleaning agent.

Replacing batteries

Used batteries are displayed as follows:

Prerequisite

Two new alkaline manganese batteries of 
type AA, 1.5 V, are ready.

1

Remove the cover plate.

2

Replace the batteries.

Remove the battery box and 
disconnect the cables.

Replace the batteries.

Connect the cables and install the 
battery box.

3

Mount the cover plate.

Maintenance

Interval

Clean the surface of 
the cover plate

Weekly

Clean the urinal 
ceramic

Daily

Replace batteries

When the battery 
indicator lights up

Have the basket filter 
cleaned by a skilled 
person

At least every 
2 years

Aggressive and scouring cleaning 
agents may damage the surface of 
the cover plate and sensor window. 
Never use aggressive cleaning 
agents that contain chlorine or are 
acidic, abrasive or corrosive.

LED in the 
sensor 
window

Meaning

Flashing

Battery voltage is low, 
flush still actuates

Lights up

Battery is dead, flush no 
longer actuates

Do not dispose of batteries in 
domestic waste.