background image

Maintenance

Replacing the control

Loosen any screws that may be present on
both sides of the actuator plate.

NN

1

Remove the actuator plate.

2

Disconnect both cables from the control.

3

Extract the control.

4

Insert the new control.

4516380043 © 10-2018
966.335.00.0 (01)

15

Summary of Contents for Sigma10

Page 1: ...MAINTENANCE MANUAL...

Page 2: ......

Page 3: ...ration 7 Making settings using Geberit Service Handy 7 Troubleshooting 12 Deactivating automatic flush actuation 13 Maintenance 15 Replacing the control 15 Replacing the lifting device 17 Testing infr...

Page 4: ...oduct Intended use The Geberit WC flush control with Sigma10 actuator plate is intended for flush actuation with Geberit Sigma concealed cisterns Safety notes Only use original spare parts when making...

Page 5: ...is detected manual flush actuation is deactivated This prevents a flush from being inadvertently released if the user leans back during use If the user s hand crosses the boundary of the manual flush...

Page 6: ...a FP a FP a FP Figure 1 Detection ranges 1 User detection range 2 Manual flush detection range 3 Proximity detection range 6 4516380043 10 2018 966 335 00 0 01...

Page 7: ...tional maintenance functions can be performed and individual settings can be made The numbers and terms in the column Menu item correspond to what can be seen on the display of the Geberit Service Han...

Page 8: ...or the proximity detection range is activated LED lights up user movement in the detection range 23 CleanMode Reinigung Activate cleaning function The control is inactive for the duration of the enter...

Page 9: ...OFF ON 31 ManFlshEn FreiManSp Activate manual flush On ON Off OFF ON 32 PowOnFlsh NetzEinSp Select power on flush If the mains voltage is on a flush is released by the control Releasing the central f...

Page 10: ...ctRng ErfassDis Specify size of WC ceramic appliance The size of the WC ceramic appliance is relevant for detection of seated user 0 1 0 short 1 long 1 1 44 DetectT VerweilZ Set detection time Minimum...

Page 11: ...mber of full flushes since commissioning flushes 56 PartFlsh SumTeilM Total number of manual partial flushes Displays the number of partial flushes since commissioning flushes 57 IntFlush SumIntSp Tot...

Page 12: ...for the flush valve Fill valve defective Replace the fill valve The WC ceramic appliance is not being flushed out properly Flush volumes set incorrectly Set the correct full flush volume on the flush...

Page 13: ...sh control is ready for operation Loosen any screws that may be present on both sides of the actuator plate NN 1 Remove the actuator plate To ensure that the conversion is successful the following ste...

Page 14: ...in the screws on both sides of the actuator plate NN 5 To test that automatic flush actuation has been deactivated place your hand at a distance of 2 3 cm from the actuator plate FP 14 4516380043 10 2...

Page 15: ...Loosen any screws that may be present on both sides of the actuator plate NN 1 Remove the actuator plate 2 Disconnect both cables from the control 3 Extract the control 4 Insert the new control 45163...

Page 16: ...the cable suspension 6 Reconnect the power supply cable on the left hand side to the control The indicator light flashes and a signal tone sounds 3 times 7 Mount the actuator plate If necessary screw...

Page 17: ...en any screws that may be present on both sides of the actuator plate NN 1 Remove the actuator plate 2 Disconnect both cables from the control 3 Remove the tension wedge 4 Turn the distance bolts 4516...

Page 18: ...tract the mounting frame 7 Extract the protection plate 8 Extract the lifting device 9 Remove the protective foil from the new lifting device 10 Mount the new lifting device 11 Mount the protection pl...

Page 19: ...12 Mount the mounting frame PP 13 Secure the distance bolts in place 14 Secure the tension wedge in place 15 Turn the actuator rod clockwise 4516380043 10 2018 966 335 00 0 01 19...

Page 20: ...he cable suspension 17 Reconnect the power supply cable on the right hand side to the control The indicator light flashes and a signal tone sounds 3 times 18 Mount the actuator plate If necessary scre...

Page 21: ...are and cleaning ATTENTION Surface damage caused by aggressive and scouring cleaning agents Never use cleaning agents that contain chlorine or which are acidic abrasive or corrosive Geberit recommends...

Page 22: ...22 4516380043 10 2018 966 335 00 0 01...

Page 23: ...4516380043 10 2018 966 335 00 0 01 23...

Page 24: ...Geberit International AG Schachenstrasse 77 CH 8645 Jona documentation geberit com www geberit com 966 335 00 0 24 4516380043 10 2018 966 335 00 0 01...

Reviews: