Tightening the gland
1
Close the ball valve.
2
Demount the actuator lever.
A gland that is tightened too securely
will cause the actuator lever to be
stiff.
3
Tighten gland to torque specified in
Table 4.
4
Mount the actuator lever.
5
Check function and ball valve for
tightness. → See "Checking the
Geberit Mapress ball valve for
tightness", page 17.
Table 4: Gland torque
d
[mm]
1P
15
13
10
22
13
10
28
17
10
35
17
10
42
19
10
54
19
10
76.1
32
30
88.9
32
30
108
32
30
18
18014400979558027-1 © 07-2018
967.965.00.0 (01)