![Geberit ACO 203 Operation Manual Download Page 32](http://html1.mh-extra.com/html/geberit/aco-203/aco-203_operation-manual_4035883032.webp)
EN
Rectifying malfunctions
Error
Cause
Action
Unable to activate the
pressing tool out of idle
state and no LEDs are lit.
Rechargeable battery
is defective.
▶ Replace the rechargeable battery
with a Geberit lithium-ion battery of
type Milwaukee 18 V.
▶ Have the defective rechargeable
battery tested by an authorised repair
shop.
The rechargeable
battery has not been
inserted properly.
▶ Insert rechargeable battery.
Pressing tool is
defective.
▶ Have the pressing tool inspected by
an authorised repair shop.
Green LED flashes.
Rechargeable battery
not charged up suffi-
ciently.
▶ Charge the rechargeable battery or
replace it with a Geberit lithium-ion
battery of type Milwaukee 18 V.
Retaining pin has not
been inserted
correctly.
▶ Insert the retaining pin.
Retaining pin has
come loose.
▶ Insert the retaining pin.
▶ Check the pressing operation and
repeat if necessary.
Red LED flashes.
Pressing tool is
outside of the
operating
temperature.
▶ Bring the pressing tool into a warmer
environment or leave it to cool down.
▶ Bring the pressing tool to the required
operating temperature by performing
multiple blank pressing operations
(pressing operations without a fitting).
Incorrect or defective
rechargeable battery
inserted.
▶ Replace the rechargeable battery
with a Geberit lithium-ion battery of
type Milwaukee 18 V.
Red LED lights up.
Tool failure.
▶ Press the start button. If pressing the
start button is not successful, the
pressing tool is defective. Have the
pressing tool inspected by an
authorised repair shop.
▶ Check the pressing operation and
repeat if necessary.
32
45035998168595595-1 © 02-2019
968.361.00.0(01)
Summary of Contents for ACO 203
Page 2: ......
Page 162: ...162 45035998168595595 1 02 2019 968 361 00 0 01...