Troubleshooting
Malfunction
Cause
Measure
No flush
actuation
Water supply interrupted
▶ Check water supply connection.
Basket filter clogged
▶ Clean or replace the basket filter.
→ See "Cleaning the basket
filter", page 18.
Solenoid valve defective
▶ Replace the solenoid valve.
Cable connection interrupted
▶ Check the cable connection to
the solenoid valve.
Battery dead; red LED lights up
permanently or not at all
▶ Replace the battery. → See
"Replacing the battery",
page 18.
Voltage supply interrupted
▶ Check the fuse in the electrical
distributor.
▶ Have the mains cable tested by
an electrically skilled person.
Decrease in flush
volume
Reduction in water supply
▶ Check water supply connection.
Basket filter clogged
▶ Clean or replace the basket filter.
→ See "Cleaning the basket
filter", page 18.
Solenoid valve defective
▶ Replace the solenoid valve.
Water is running
continuously into
the urinal
ceramic
appliance
Solenoid valve defective
▶ Replace the solenoid valve.
9007203488149771-1 © 07-2019
968.958.00.0(01)
17