Fig.23
Notice
Valve disk has sharp edges
When the valve is installed in the valve housing, the lower rod seal can
become damaged by the valve disk (15).
► For this reason, an assembly mandrel (M) must always be used.
Carry out the following steps:
1.
Insert assembly mandrel (M) with O-ring side in valve disk (15).
2.
Insert valve into housing with assembly mandrel.
3.
Remove assembly mandrel from valve disk.
®
Done
10.7.5 Checking assembly
Fig.24
When the valve is closed, the lower edge of the cleaning hood (1) should be flush
with the underside of the abutment (2).
10.7.6 Reconnect the cleaning hose