Mount the O-ring (25) using the installation mandrel.
10.7.2 Guide rings
Fig.19
After installing the double disk (16) and the leakage outlet (14), push the guide
ring (21) through the opening in the leakage outlet and install.
10.7.3 Spring
Fig.20
Before the spring is placed into the cleaning hood, both surface ends must be
greased.
10.7.4 Leakage pipe
Before installation, rub the sealing pin (pipetite stick, material no. 418-017)
several times over the male thread of the leakage pipe. The spreadable sealant
presses itself between the threads when screwed together and seals
permanently and without hardening.
10.7.5 Torques for the Clamps and Clamp Connections
Tighten the clamp connection and semi-rings on the valve to the torques
specified in the table.
Maintenance
Installation
430BAL008372EN_4