Fig.36
2.
Screw the mounting base (198) into the actuator (A4) and tighten using a face
spanner.
3.
Screw switch bar (1) with ring (99) into the piston rod (A4.1) and tighten with
open-end wrench SW 13, torque 2 Nm (1.4 lbft).
4.
Fit the control top (B) over the switch bar (1) and on the actuator.
5.
Tighten the clamps (15) and screws (39) to a torque of 1 Nm (0.7 lbft).
6.
Align the pneumatic and electrical connections in accordance with the valve
block configuration.
7.
As internal air guiding is not possible on VESTA valves, connect the air
connection (Y1) on the control top to connection A4.2 on the actuator with an
air hose (L).
8.
Perform commissioning, see Chapter 6, Page 41 and Chapter 7, Page 67.
®
Done.
6.6.8
Mounting to VESTA Valve H_A/M
Requirement:
•
Pay attention not to kink the air hoses when mounting the control top.
Carry out the following steps:
1.
Place O-rings (139.2) in the adapter (139) at the bottom side of the thread
(139.1).
Assembly and installation
Mounting the control top to different valves
430BAL010699EN_6
62
17.03.2022
Summary of Contents for T.VIS A-15
Page 6: ...430BAL010699EN_6 6 17 03 2022...
Page 116: ......