D
GB
F
E
11
96416-08.2020-DGbFEIRu
4
|
Areas of application
ATTENTION
When operating in the vacuum range, there is a danger of air
entering on the suction side. This can cause chemical reactions,
a pressure rise in the condenser and an elevated compressed-gas
temperature. Prevent the ingress of air at all costs!
Maximum admissible
operating pressure (g)
(LP/HP)
1)
: 19/28 bar
1)
LP = Low pressure
HP = High pressure
Summary of Contents for HG44e