ZVB30SH/BH/WH – GE Monogram 30" Telescopic Downdraft Vents

Specification Created 10/03 

130658

Creative Solutions

For answers to your Monogram,

®

 GE Profile

 or  

GE

®

 appliance questions, visit our website at  

GEAppliances.com or call GE Answer Center

®

  

service, 800.626.2000.

Listed by  

Underwriters  

Laboratories

R

Against-the-wall installation 

Move the base cabinet forward, 3" to 5". 

Filler panels or complimentary moldings can 

be added to the exposed cabinet sides.

Island or peninsula installation 

Use an extra-deep countertop. The countertop 

overhang at the front can be adjusted to meet 

setback to cutout requirements.

Decorative trim 

When the cutout to front edge of the  

countertop requirement is more than 2",  

add a bullnose trim to the front edge of the 

countertop. The additional trim allows the 

cooktop to be moved forward, providing  

additional countertop depth and interior 

cabinet space. 

605Dia159

Base Cabinet

Filler Panel

Base Sink

Filler Panel

Maintain Cutout Clearances

to Front Edge as Specified

605Dia160

Cover Panel

Base Sink

End

Panel

Countertop Overhang per Cooktop

Clearances Must be Maintained

605Dia161

DOWNDRAFT 

VENT

1-7/8"

Trim

Add a Bullnose 

Trim or Decorative 

Molding to 

Increase 

Countertop 

Depth and to 

Maintain 

Required 

Clearance From

Front Edge 

Optional Accessories

JXRB67

 Accessory for indoor remote location 

of the blower/motor assembly. Use this kit 

when the blower and motor assembly will 

be located outside of the cabinet, such as 

below the cabinet floor. The assembly will fit 

between 16" floor joists.

JXBC67

 Outdoor cover accessory for remote 

installation of the blower/motor assembly on 

an outside wall.

Ductwork

Prepare the ductwork to vent to the outdoors. 

•  Plan the shortest and straightest route for 

venting exhaust to the outdoors. 

•  The maximum permissible length for the 

duct run is 150 feet.

• Use metal ductwork only.

•  The downdraft blower system is designed to 

use 3-1/4" x 10" duct. It can be transitioned 

to 6" round.

•  Install a wall cap or roof cap with damper at 

the exterior opening. Order the wall cap and 

any transition needed in advance.

Summary of Contents for ZVB30SH/BH/WH

Page 1: ...vidual dimension drawings for the combined vent and Monogram cooktop installation Before you begin you must 1 Review countertop dimension illustrations to be sure you will have enough flat countertop surface depth 2 Check to be sure that the total countertop depth required including minimum cutout to front edge depth allows enough space for a backsplash 3 Review the cabinet illustration Check to be...

Page 2: ...ller Panel Maintain Cutout Clearances to Front Edge as Specified 605Dia160 Cover Panel Base Sink End Panel Countertop Overhang per Cooktop Clearances Must be Maintained 605Dia161 DOWNDRAFT VENT 1 7 8 Trim Add a Bullnose Trim or Decorative Molding to Increase Countertop Depth and to Maintain Required Clearance From Front Edge Optional Accessories JXRB67 Accessory for indoor remote location of the b...

Page 3: ...rical outlet within reach of the vent s two foot long power cord Locate the outlet inside the cabinet on the right side wall If the vent is installed in combination with a Monogram gas cooktop it may operate from the same 120V standard duplex outlet If the vent is installed in combination with a Monogram electric cooktop the vent must operate from a separate 120V outlet 682Dia49 Discharge Down As ...

Page 4: ...ounted control Variable speed fan with slide control Raises to 8 1 2 over cooktop surface Retracts when not in use Removable grease filters 3 1 4 x 10 rectangular duct Optional remote blower capabilities Stainless steel vent body Minimum 6 round duct capabilities Model ZVB30SHSS Stainless steel shown Model ZVB30WHWW White on white Model ZVB30BHBB Black on black 682Dia23 ...

Reviews: