4
1.Remove the 4 decorative screws and washers on the
top of the glass.
2.Slide the glass forward about one inch.
3.Use a Phillips head screwdriver to remove the 2
screws holding the display control box to the hood.
4.From the front of the hood, push the control box
towards the back. Lift the control out of the top
of the hood.
5.Unplug the control connector.
To Remove the Display Board
Should the glass canopy gasket need replacement,
no adhesive is required. Adhesive is used in the
factory assembly, but is not required for the
replacement gasket.
Canopy Gasket Replacement
1.Remove the inner lamp lens cover by inserting a small
flat blade screwdriver into each of the three slots and
gently prying it free.
NOTE:
Do not remove the outer trim ring (lamp
assembly).
2.Grasp the bulb and pull it straight out.
3.Replace with the same wattage, type and size
bulb. Wear gloves. Do not touch bulb with your
bare fingers.
4.Replace inner cover by inserting the three
retaining tabs into the three slots and pressing
them firmly in place.
NOTE: If “WRONG WATT BULB” appears in the display,
the wrong type of replacement bulb has been used.
Replacement bulbs must be 12 volt, 20 watt halogen
bulbs with a G4 base. Use part no. WR02X11184
replacement bulbs.
To Replace the Light Bulbs
Control box
Remove screws
Note: Wall Mount Hood shown,
follow the same procedures for
the island hood.
Step 1
Step 2
Step 3
Step 4
Use a small flat blade screwdriver to
remove the inner lamp lens cover.
Outer trim ring
(lamp assembly)
Do not remove
Bulb
Removable inner
lamp lens cover
NOTE:
Make sure the tabs are inserted into the slots.