GE ZV900SL3SS Installation Instructions Manual Download Page 9

Summary of Contents for ZV900SL3SS

Page 1: ...Installation Instr ct 36 Glass Canopg Chimneg Vent Hood ZV900 49 80328 3 Monogram ...

Page 2: ...ngswitched on occidentollg If the service ponelconnotbe locked fosten o togor prominent worningIobel totheponel AAVERTISSEMENT POUR REDUIRE LE RISQUE D INCENDIE DE CHOC I_LECTRIQUE OU DE BLESSURES IL FAUT OBSERVER LES REGLES SUIVANTES A Utiliser cet opporeil uniquement de Io moniGre prGvue pot le fobricont Encos de question consulter le fobricont B Avont toute intervention ou nettogoge couper I ol...

Page 3: ... Size and Cut Duct Piece 18 Step 8 Connect Electrical 18 Step 9 install Duct Covers 19 Step 0 install Filters 19 Step Finalize installation 19 PRODUCT DIMENSIONS AND CLEARANCES r Height to Ceiling 3 1 4 20 7 16 _ The Supplied Duct Cover Fits 8 to 9 5 Ceiling Heights For 9 6 to 10 5 ceilings order zxg00 0 The vent hood must be installed 24 min and 30 max above the cooking surface The hood installat...

Page 4: ... accessory should be ordered with the hood and be on site before installation begins POWER SUPPLY IMPORTANT Pleaseread carefullg AWARNING FOR PERSONAL SAFE THIS APPLIANCEMUSTBEPROPERLY GROUNDED VERTISSEMENT POUR DES RAISONSDE SE_CURITE CETAPPAREIL DOITETRECORRECTEMENT MISE _ LATERRE Removehouse fuse or open circuit breaker before beginning installation Do not use an extension cord or adapter plug ...

Page 5: ...t_t standards such as those published bbt NFPA and ASHRAE When applicable install anbt makeup replacement air sbtstem in accordance with local building code requirements Visit GEAppliances com for available makeup air solutions Equivalent Duct Piece Dimensions Length Round 1 ft straight per foot length Total guantitg Equivalent Used Length 3 4 x 2 ft straight per foot length 90 elbow 7ft 0 ft 45 e...

Page 6: ... drill with 5 16 and 3 8 Bits Safetg glasses Phillips _ head screwdriver Saw jig saw or Masking tape reciprocating saw Gloves Knife Wire cutter stripper Hammer Flat blade screwdriver 8 round metal duct length to suit installation REMOVE THE PACKAGING CAUTION L FT THE HOOD OUT OF THE BOX BYTHE CENTER METAL PORTION DO NOT LIFT BY THE GLASS SIDES PRU DENCE LEVEZ LA HO_E A L EXTERIEURDE LA BO TE PAR L...

Page 7: ... 5 This accessorg contains one 40 long duct cover Actual Ceiling Height 7 11 8 0 8 1 8 2 8 3 8 4 Possible VENTED Installation Height 24 to 26 24 to 27 24 to 28 24 to 29 24 to 30 24 to 30 Possible RECIRCULATING Installation Height 24 to 26 24 to 27 24 to 28 24 to 29 24 to 30 24 to 30 8__5 _ 8__6 _ 8 7 8 8 8 9 8 0 24 to 30 24 to 30 24 to 30 24 to 30 24 to 30 24 to 30 24 to 30 24 to 30 24 to 30 24 to...

Page 8: ...PACKAGE Locate and count screws 3 wall fasteners 12 hood attachment screws 3 wall bracket screws Air deflector for recirculating installation onlg 27 3 4 11_u 1 Duct bracket 2 piece decorative duct 23 7 8 cover dimension shown for reference onlg _r HALL t_ Wall mount template 1 charcoal filter for recirculating installation Stainless steel filter 0_0 _ Mounting bracket ...

Page 9: ...nsion Wall Ducting If ductwork will vent to the rear Use a level to draw a line straight up from the centerline on the template Measure at least 26 above the pencil line that indicates the bottom installation height to the centerline of an 8 1 2 dia duct hole Hole mag be elongated for duct elbow HOUSEWIRING LOCATION Thejunction box is located on the top left side of the hood Wiring should enter th...

Page 10: ...led horizontal mounting support Check to be sure that the bracket is level INSTALL DUCT BRACKET The duct bracket should be installed against the back wall and flush with the ceiling This bracket will hold the duct cover in place at the top Secure the bracket to the wolh Align the marked centerline on the bracket with the centerline on the wall Mark 2 screw hole locations in the wall Drill 3 26 pil...

Page 11: ...face the front with rear mounting hooks at the back Slip the bottom flange of the motor housing into the side slots at the top rear opening Rear view Rear mounting hooks Carefullg lag the hood on its back Fasten the hood to the motor housing from the bottom using 6 screws Front side Join two cable connectors at the front of the hood Engage flange on motor housing into slots Control Panel 11 ...

Page 12: ...at the bottom of the hood Remove the hood If the bottom screw hole does not enter a stud enlarge the hole to 3 8 and install wall fastener anchors Place the hood back onto the mounting bracket check level again and install the wall fastener _ CONNECT DUCTWORK Install ductwork making connections in the direction of airflow as illustrated Push duct over the exhaust outlet and damper Secure joints in...

Page 13: ...re Ouand les ills sont en aluminium il faut prendre soin d utiliser des connecteurs aluminium a cuivre avec une pate antioxgdante approuv6e par U L Removejunction box cover and knockout on the left side Knockout Secure the house wiring to the junction box with a strain relief House wiring J Box cover Connect white leads to branch circuit white lead Connect black leads to branch circuit black lead ...

Page 14: ...acket Duct cover support bracket Lower duct cove_ _ Lower duct _ _ A cover seat Extend the inner duct upward to the ceiling bracket Secure duct cover to ceiling bracket with 2 screws INSTALL FILTERS IMPORTANT Check to be sure that the main ON OFF switch next to the motor is in the ON position Remove protective film on the filters Filter Lock NOTE The charcoal filter is not required for this instal...

Page 15: ...ft side of the hood Wiring should enter the back wall at least 22_ above the bottom of the hood and within 6_ of the centerline INSTALL FRAMING FOR HOOD SUPPORT IMPORTANT Froming must be capable of supporting 100 Ibs I Centerline of installation space View from rear cleats 1 x 6 min mounting support If drgwall is present mark the screw hole locations for the top mounting brackets Remove the templa...

Page 16: ...ounting support Check to be sure that the bracket is level _ INSTALL DUCT BRACKET The duct bracket should be installed against the back wall and flush with the ceiling This bracket will hold the duct cover in place at the top Secure the bracket to the wall Align the marked centerline on the bracket with the centerline on the wall Mark 2 screw hole locations in the wall Drill 3 164 pilot holes in t...

Page 17: ... position the hood onto the mounting bracket AVERTISSEMENT If faut deux personnes pour lever et mettre en place la hotte sur le support de montage Lift the hood onto the mounting bracket Position a spirit level at the bottom of the hood to check side to side leveling LEVEL THE HOOD This hood has built in levelers on the mounting hooks at each side Use a long Phillips screwdriver from the front to ...

Page 18: ...g is not 2 wire with a ground wire a ground must be provided bg the installer When house wiring is aluminum be sure to use U L approved anti oxidant compound and aluminum to copper connectors AVERTISSEMENT Si la maison n est pas c blee avec deux ills et un fil de terre I installateur dolt installer un fil de terre Ouand les ills sont en aluminium il faut prendre soin d utiliser des connecteurs alu...

Page 19: ...uct cover support bracket Lower duct cover seat Extend the inner duct upward to the ceiling bracket Secure duct cover to ceiling bracket with 2 screws INSTALL FILTERS IMPORTANT Check to be sure that the main ON OFF switch next to the motor is in the ON position Charcoal filter i i Install the black charcoal filter into the center opening Secure the filter with thumbscrews on each side Metal filter...

Page 20: ...uld be worn For Monogram _ local service in your area call 1 800 44 18 5 NOTE Product improvement is a continuing endeavor at General Electric Therefore materials appearance and specifications are subject to change without notice Monogram GE Appliances Lighting Appliances General Electric Company Louisville KY 40225 monogram corn ...

Reviews: