background image

AZ58H09E – GE Zoneline

®

 Premium Series Heat Pump Unit

Specification  Created 9/04

390569

GE Appliances

Electrical Wiring

All wiring, including installation of receptacle, must be made in 

accordance with local electrical codes and  regulations.

Note:

Aluminum wiring may pose special problems – consult 

a qualified electrician.

Grille Options

Stamped Aluminum Grille – RAG60
Exterior Architectural Louvers Durable Polycarbonate:
RAG61 or RAG64 (Beige) 

RAG63 or RAG66 (Bittersweet)

RAG62 or RAG65 (Maple)  RAG67 (Extruded Aluminum)

Retrofit Kits:

RAK901L – Wall Case Insulation for use with heat pumps.

RAK40 – Deflector Kit to adapt chassis for use with existing 

exterior architectural louvered grilles.

Electrical Connection

230/208 volt units may be plugged into a receptacle. 265 volt 

units are provided with a junction box and require direct 

connection. (NEC Requires 265V Direct Connection) See 

Architects and Engineers Design Data Manual for  electrical 

connection information including use of sub-base for direct 

connected units. Installation must  comply with local electrical 

codes and regulations.

Power Connection kits required on all Zoneline chassis.

A

C

B

Zoneline RAC Wall Installation

Zoneline Wall Install QSart

Wall Case Dimensions

RAB71 Wall Sleeve

Heavy-gauge galvanized steel, with insulation. 

  A  – 42", B – 13-3/4", C – 16"

RAB77 Wall Sleeve

Molded SMC fiberglass-reinforced polyester compound. 

  A – 42-1/8", B– 13-7/8", C – 16-1/4

Wall Opening Dimensions

Add 1/4" to A and C dimensions for all cut-out size.

  RAB71 16-1/4" Min. H x 42-1/4" Min. W

  RAB71 available in 16", 24", 28" and 31" depths

  RAB77 16-1/2" Min. H x 42-3/8" Min. W

Maximum Cord Extension (in inches)

For answers to your Monogram,

®

 GE Profile

 or 

GE

®

 appliance questions, visit our website at

ge.com or call GE Answer Center

®

 service, 

800.626.2000.

SIDE

VIEW

Inside

Room

  Cabinet

Outside

58

21

Grille

7-1/8

RAB71A = 16
RAB77A = 16-1/4

RAB71A = 20-7/8
RAB77A = 21

Room Air/Installation QSart

265 Volt Sub-Base Connected Units

Sub-Base

Power 

Connection Kit

Electric 

Heater Watts

Electric 

Heat Amps

Min. Circuit 

Protection 

(Amps)

RAK204E15

RAK5172

2,550

10.3

15

RAK204E20

RAK5202

3,450

13.7

20

RAK204E30

RAK5302

5,000

19.6

30