– 20 –
(Continued next page)
Power Connector Plug 20-AMP - 230/208 VAC,
3.30/3.20 KW Heat (RAK3203A)
The L1 side of the line is connected to terminal #3,
and L2 is connected to terminal #7. The ground wire
is connected to terminal #5. There are jumper wires
between terminals #1 and #2 and #2 and #6.
#1 TERM
KEY
LATCH
TERMINAL END VIEW
BOTTOM
RAK3203
L2
L1
G
Heater Circuit Schematic 20-AMP - 230/208 VAC,
3.30/3.20 KW Heat (RAK3203A).
When the relay contacts close, the circuits to the
1.0 KW and 2.3 KW heaters are completed from L1
through the jumpers between terminals #1 and #2,
#2 and #6, and back to L2 through terminal #7. This
makes a total of 3.30/3.20 KW of heat available to
heat the room.
Power Connector Plug 30-AMP – 230/208 VAC,
4.70/4.53 KW Heat (RAK3303A)
The L1 side of the line is connected to terminal #3,
and L2 is connected to terminal #7. The ground wire
is connected to terminal #5. There are jumper wires
between terminals #1 and #2, #2 and #6, and #4 to
#9.
#1 TERM
KEY
LATCH
TERMINAL END VIEW
BOTTOM
RAK3303
L2
L1
G
Heater Circuit Schematic 30-AMP - 230/208 VAC,
4.70/4.53 KW Heat (RAK3303A)
When the relay contacts close, the circuits to the
1.0KW, 1.4 KW, and 2.3 KW heaters are completed
from L1 through the jumpers between terminals
#1 and #2, #2 and #6, #4 and #9, and back to L2
through terminal #7. This makes a total of 4.70/4.53
KW of heat available to heat the room.
3
9
8
5
UNIT WIRING
POWER CONNECTOR WIRING
TRIAC
1.0 KW
1.4 KW
2.3 KW
ACTIVE L1 CIRCUIT
ACTIVE L2 CIRCUIT
INACTIVE CIRCUIT
9
8
6
5
1
2
4
3
1
4
2
L1
L2
208/230V
JUMPER
GND
GND
GND
RAK3203A
PROTECTOR
FUSE
RELAY
7
7
HEATER CIRCUIT - 230/208 VAC
3.3 KW HEAT
6
3
8
5
UNIT WIRING
POWER CONNECTOR WIRING
TRIAC
2.3 KW
ACTIVE L1 CIRCUIT
ACTIVE L2 CIRCUIT
INACTIVE CIRCUIT
9
8
6
5
1
2
4
3
1
4
2
L1
L2
208/230V
JUMPER
GND
GND
GND
RAK3303A
PROTECTOR
FUSE
RELAY
7
7
HEATER CIRCUIT - 230/208 VAC
4.7 KW HEAT
6
9
1.4 KW
1.0 KW