Page 1: ...Manual Important Safety information Operating Instructions The OontroL_ on Yo_r ZoneH_m Oa_ o Predator Installation Instructions Helpful Information Thi_gs Tha_ _ Are If SomethingGoes Wrong BeZoye Yow...
Page 2: ...he room cabinet on the base pan Model number Serial number Date of purchase ii _ il Hglp 1is help you 800 626 2000 Befi re you call for service there are a few things you can do to help us serve you b...
Page 3: ...tructions before it circuit breaker before making is used See pages 10 12 Repair or replace immediately all electric service cords that have become ficayed or otherwise damaged SAVE any repairs NOTE W...
Page 4: ...become warmer 3200 Series on y When the outdoor temperature is lower than 25 F heat is provided by the electric heater in the air conditioner instead of by the heat pump A Mode Control HiGH COOLand L...
Page 5: ...unit behind the room cabinet When set at CLOSE only the air inside the room is circulated and filtered When set at OPEN some outdoor air will be drawn into the room This will reduce the heating or co...
Page 6: ...in order to reach the new temperature setting quickly There is a three minute minimum compressor run time at any setting to prevent short cycling The indoor fan motor starts before the compressor and...
Page 7: ...on of room air and will resuh in a more balanced temperature throughout the room If you want the fan to cycle on and offwith the compressor or with the heater move the switch to cycle fan UP 123456 UP...
Page 8: ...hey may be profes sionally steam cleaned a seiMce available through your GE seiMce outlet You will need to remove the chassis to inspect the coils because the dirt build up occurs on the inside Clean...
Page 9: ...er through the filters Dry thoroughly before replacing To remove the air filters 2 air filters To replace the air filters Push down clogged filter Greatly reduces cooling heating and airflow CAUTION D...
Page 10: ...may be used with grilles that were not designed for your new GE Zonelines The RAK40 contains air deflectors and gaskets that mount to the chassis to direct the hot exhaust air away from the air intak...
Page 11: ...o not use an extension cord with this uniL Aluminum building wiring may present special problems consult a qualified electrician When the unit is in the STOP position there is still voltage to the ele...
Page 12: ...net 23_ iloIt EIectrical_ly All wiring including installation of the receptacle must be in accordance with the NEC and local codes ordinances and regulations This unit is equipped with a line cord for...
Page 13: ...is to be cut and the wire ends stripped and connected as follows Steps for preparing cordset for direct connection 1 Remove the junction box cover by taking out the front four screws 2 Junction box co...
Page 14: ...aligning the screw hole at the top and driving the one screw until secure Be sure that all wire leads are inside the box and not pinched between the box and the chassis The identified ribbed Neutral...
Page 15: ...n the room side of the case The RAB71 wall case is insulated Insulation kit RAK901L is available for use with RAB77 or existing uninsulated wall cases when needed NOTE For installation with a subbase...
Page 16: ...ws through the unit flange holes If an insulated wall case is needed see Install the Wall Case and Exterior Grille section on the previous page Reinstall the room cabinet by hooking the top over the r...
Page 17: ...ch to the O V up position 123456 UP BBBBB lDowN Auxiliary controls i Temperature Limiting Temperature limiting can reduce energy costs by limiting the lowest temperature that can be set fl r cooling a...
Page 18: ...Control C C switch 5 you must have an Optional Interface Module kit See the Installation Instructions with accessoi T kit RAKOIM 123456 IBBBB BI o Switch 4 controls the All Time Low Fan and is only ef...
Page 19: ...ling mode unless the fan switch behind the room cabinet is set at fan cycle up This will cause the fan to cycle on and offwith the compressor You may also hear a fan noise stop and start You may notic...
Page 20: ...rload For this reason the unit may not start normal heating or cooling fi r 3 minutes after it is turned back on Indoor airflow is restricted Make sure there are no curtains blinds or furniture blocki...
Page 21: ...as hot as air produced when the higher cost electric heat is used The fan switch may be set at continuous fan down This causes the tan to blow room temperature air even when the compressor or heater c...
Page 22: ...Notes 22...
Page 23: ...ons con tained in this manual cover proce dures to be performed by any user Other servicing generally should be referred to qualified service person nel Caution must be exercised since improper servic...
Page 24: ...he air conditioner is of improper cooling capacity tiw the intended use contact your dealer or installer You are responsible fiw providing adequate electrical connecting facilities Replacement of fils...