GE Zoneline 1000 Series Use And Care Manual Download Page 2

Help us

 Safety

Energy-Saving

help you...

Instructions

Tips

Before using your
air conditioner, read
this book carefully.

It is 

intended to help you operate

and maintain 

your new air

conditioner properly.

Keep   handy for answers 

to your

questions.

If you don’t understand something

or need more help, write (include
your phone number):
Consumer Affairs
GE Appliances
Appliance Park

Louisville, KY 40225

Write down the model
and serial numbers.

You’ll find them on a label behind

the room cabinet.

These numbers are also on the
Consumer Product Ownership
Registration Card that came with
your air conditioner. Before sending
in this card, please write these
numbers here:

Model Number

Serial Number

Use these numbers in any
correspondence or service calls
concerning your air conditioner.

If you received a damaged air
conditioner,  
immediately contact
the dealer (or builder) that sold
you the air conditioner.

Read 

 

 before

using this 

appliance.

When using this appliance, always
exercise basic safety precautions,
including the following:

● 

Use this appliance only for its

intended purpose  as described in
this Use and Care Book.

● 

This air conditioner must be

properly installed in accordance
with the Installation Instructions
before it is used.

. Never use an 

 cord

with this appliance.

 THESE

INSTRUCTIONS

 Keep the air filter clean. (See

instructions on page 5.)

● 

For most efficient operation,

keep vent in closed position except
when you want to let outside air
enter the room.

● 

Don’t let the room get too hot or

too cold. Whenever possible, turn
the unit on before the room heats
up or cools off. If you don’t, the air
conditioner will take longer to
produce the desired comfort
condition.

● 

Keep windows and doors closed.

Conditioned air escapes when
they’re open.

● 

Keep furnace floor registers and

cold air returns closed when cooling
is desired. Conditioned air can
easily escape through them.

● 

Don’t let drapes or furniture block

the front of the unit and restrict air
flow when it is operating.

● 

It’s best to operate your air

conditioner at high speed during
extremely hot or cold weather.

● 

Keep the outdoor condenser coil

clean. (See page 5.)

● 

Turn the air conditioner off

before vacations or extended
absences.

Save time and money.
Before you request service,
check the Problem Solver on
page 6. It lists causes of minor
operating problems that you
can correct yourself.

2

Summary of Contents for Zoneline 1000 Series

Page 1: ... Coils 5 Energy Saving Tips 2 Fan Cycle Switch 4 Master Controls 3 Model and Serial Numbers Problem Solver Repair Service 7 Room Cabinet and Case 5 Safety Instructions 2 Thermostat Control 3 Ventilation Control 4 Warranty Back Cover GEAmww CetieP 8W 2 0 Heat Cool fineline Models 1000 Series 2000 Series GEAppfancw ...

Page 2: ...d purpose as described in this Use and Care Book This air conditioner must be properly installed in accordance with the Installation Instructions before it is used Never use an tension cord with this appliance SAW THESE INSTRUCTIONS Q Keep the air filter clean See instructions on page 5 For most efficient operation keep vent in closed position except when you want to let outside air enter the room...

Page 3: ... nding n which fan speed setting you serect HEAT permits heating with low fan speed or high fan speed operation depending on which fan speed setting you select Air buvers For best heat distribution tilt the louvers down so the heated air is directed across the room For best distribution of cold air tilt the louvers up so the cold air is directed towards the ceiling I HIGH LOW FAN SPEED I Fan Speed...

Page 4: ...is knob is set at CLOSE at the factory When it is in this position the vent door is closed and only indoor air is filtered cooled or heated and circulated by the air conditioner Switching the knob to OPEN opens the vent door to allow some outside air to enter the room However cooling or heating effectiveness is reduced when the control is set at OPEN so we suggest you don t keep it there long L J ...

Page 5: ...ashed at least every 30 days or as often as it needs cleaning Access to the filter is obtained by removing the room cabinet See page 4 To remove the air filter grasp the pull tabs on the front of the filter as shown and pull toward you until the three tabs at the top and bottom of the filter come out of the slots in the chassis Vacuum the filter on the dirty side or wash it with running water Run ...

Page 6: ...er was first turned on Allow time for it to cool down or warm up Q Conditioned air may be escaping through open furnace floor registers and cold air returns Ventilation Control may be set at OPEN position allowing outside air to enter the room Position of the louvers will affect temperature See page 3 Dust accumulating on surface of heating element during trans rtation or storage can cause burning...

Page 7: ...urther help FIRST contact the people who serviced your appliance Explain why you are not pleased In most cases this will solve the problem NEXT if you are still not pleased write all the details including your phone number to Manager Consumer Relations GE Appliances Appliance Park Louisville Kentucky 40225 FINALLY if your problem is still not resolved write Major Appliance Consumer Action Panel 20...

Page 8: ...OVERED Service trips to teach you how to use the product Read your Use and Cam material If you then have any questions about operating the product please contact your dealer or our Consumer Affairs office at the address below or call toll free GE Answer CenteP 800 626 2000 consumer information service Improper installation If you have an installation problem or if the air conditioner is of imprope...

Reviews: