– 58 –
Note:
When servicing the inverter, it is
important to dress the wiring to keep low-
voltage DC wiring and 120 VAC wiring
separate.
To remove the inverter:
1. Unplug the unit.
2. Open access cover.
3. Remove the screw securing the inverter to
the sheet metal dividing wall. (It may be
necessary for you to move the foam
spacer.)
4. Slide the inverter forward to release the
back from the metal dividing wall.
Note:
It may be necessary to bend the
process tube in order to remove the inverter. If
it is necessary to bend the process tube, use
extreme care.
5. Turn the inverter horizontally and slide the
inverter out of the machine compartment.
To remove the inverter cover:
Use a small screwdriver to release the two
small tabs and carefully remove the inverter
cover.
Compressor Lead
Wires
Compressor Lead
Wires
Signal Wire Connector
(From Main Control Board)
Inverter
Inverter
Signal Wire Connector
(From Main Control Board)
Line-In (L1)
Line-In (L1)
Tabs
Inverter
Screw