1.
Install a manual gas line shut-off valve in the
gas line in an easily accessed location outside of
the range. Make sure everyone operating the
range knows where and how to shut off the gas
supply to the range.
2. Install male 1/2” flare union adapter to the
1/2”
internal thread elbow at inlet of
regulator.
On models equipped
burners,
install the male pipe thread end of
the 1/2” flare union adapter to the
1/2” NPT
internal thread at inlet of pressure regulator.
Use a backup wrench on the regulator
fitting
to avoid damage.
installing the range from the front,
remove
the 90° elbow for easier installation.
3. Install male 1/2” or 3/4” flare union adapter
to the NPT internal thread of the manual shut-
off valve, taking care to back-up the shut-off
valve to keep it from turning.
4. Connect flexible metal appliance connector
to the adapter on the range. Position range
to permit connection at the shut-off valve.
5.
all connections have been made, make
sure all range controls are in the off position and
turn on the main gas supply valve. Use a liquid
leak detector at all joints and connections to
check for leaks in the system.
DO NOT
USE A
TO
CHECK FOR GAS
using test pressures greater than 1/2 psig
to pressure test the gas supply system of the
residence, disconnect the range and individual
shut-off
from the gas supply piping.
using test pressures of
1/2
psig or less to test the
gas supply system, simply isolate the range from
the
supply system by closing the individual
shut-off valve.
❑
CONNECTIONS
Electrical Requirements
120-volt, 60 Hertz, properly grounded branch
circuit protected by a 15-amp or
circuit
breaker or time delay fuse.
Extension Cord Cautions
Because of potential safety hazards associated
with certain conditions, we strongly recommend
against the use of an extension cord. However,
if you still elect to use an extension cord, it is
absolutely necessary that it be a
3-wire grounding-type appliance extension cord
and that the current carrying rating of the cord
in amperes be equivalent to, or greater than,
the branch circuit rating.
Grounding
read
FOR
THIS
MUST BE
GROUNDED.
power cord of this appliance is equipped
with a three-prong
plug which
mates with a standard three-prong grounding
wall receptacle
PREFERRED ‘
to
minimize the
METHOD
.\
possibility of
o
electric shock
hazard from
this appliance.
The customer
ENSURE PROPER
GROUND EXISTS
should have the
BEFORE USE
wall receptacle
and circuit
checked by a
qualified electrician to make sure the receptacle
is properly grounded.
a standard two-prong wall receptacle is
encountered, it is the personal responsibility and
obligation of the customer to have it replaced with
a properly grounded
wall receptacle.
DO
NOT, UNDER ANY
CUT OR
THE THIRD (GROUND)
PRONG FROM THE
CORD.
37