6
Resistance
Ω
Electrical component
@ 77
°
F (25
°
C)
Dispenser valve solenoids
800 ± 7%
Door lock solenoid
1325 ± 10%
Pump motor
12 ± 7%
NTC thermistor
3K - 163K
M1 TO M2
5.3 ± 7%
M2 TO M3
5.3 ± 7%
M1 TO M3
5.3 ± 7%
M4 TO M5
118 ± 7%
QUICK REFERENCE SHEET
Component resistance chart.
Water level
Water fill height 4 ± .5 “
No load, start position of permanent press cycle.
Electrical requirements.
Incoming water pressure.
Drain requirements.
Motor.
Circuit - Individual, properly polarized and grounded
15 amp. branch circuit fused with 15 amp. time
delay fuse or circuit breaker.
30 and 120 pounds per square inch (maximum
unbalance pressure, hot vs. cold, 10 psi.)
Drain capable of eliminating 17 gals (64.3 L) per
minute.
A standpipe diameter of 1-1/4 in. (3.18 cm) minimum.
The standpipe height above the floor should be:
Minimum height:
24 in. (61 cm)
Maximum height:
96 in. (244 cm)
Motor
No load agitate wattage - Max 150
No load spin wattage - Max 550
Summary of Contents for WSSH300G