background image

210575001 Rev. A 1-08

8 of 8

www.geelectrical.com

Summary of Contents for WF180

Page 1: ... Read all instructions before installing or using exhaust fan 2 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer 3 Before servicing or cleaning the unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on SAVE THESE INSTRUCTIONS IMPORTANT INSTRUCTIONS OPERATING MANUAL accident...

Page 2: ... have 1 Grill 1 Grill Knob 1 Wiring Compartment and screws 1 Motor 1 Housing 1 Instruction Safety Sheet NOTE This fan is designed to mount between exterior walls 4 1 2 to 9 1 2 in thickness 2 Remove the motor bracket assembly from the fan housing by loosening the two screws which secure the bracket in place Figure 1 3 Slide the inner housing out from the outer housing and set aside in a safe place...

Page 3: ...oles on the four corners of the housing Seal the flange where the housing meets the wall with caulk Figure 7 SECTION 3 Wiring CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION CAUTION ALLELECTRICALCONNECTIONSMUST BE MADE IN ACCORDANCE WITH LOCAL CODES ORDINANCES OR NATIONAL ELECTRICAL CODE IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING SECURE...

Page 4: ...crews Rotate the blower wheel by hand to ensure it spins freely Now plug the fan motor into the receptacle Figure 1 2 Install grill by positioning over the inner housing and aligning the center hole on the grill with the hole on the motor bracket Screw one side of the included grill bolt into the hole on the motor bracket and the other side into the grill knob and turn to tighten until the grill i...

Page 5: ...o receptacle in housing Restore power to unit 1c Wiring is not connected properly 1c Turn off power to unit Check that all wires are connected 1d Motor has stopped operating 1d Replace motor 2 Fan is operating but air moves slower than normal 2 Obstruction in the outer housing 2 Check for any obstructions where the fan exhausts to the outside 3 Fan is operating louder than normal 3a Motor is loose...

Page 6: ...llation problem contact your dealer or installer You are responsible for providing adequate electrical exhausting and other connecting facilities See the Installation Instructions provided with this product for electrical exhaust and connection details Replacement of house fuses or resetting of circuit breakers Failure of the product if it is used for something other than the intended purpose of m...

Page 7: ...et 5S2203005 6 1 Spring 5S2203006 7 1 Damper 5S2203007 8 1 Gasket 5S2203008 9 1 Gasket 5S2203009 10 1 Wire Compartment 5S2203010 11 1 Ground Screw 5S2203011 Qty Description Replacement Part 12 1 Wire Compartment Cover 5S2203012 13 1 Polarized Receptacle 5S1999001 14 1 Blade 5S2203013 15 1 Motor 5S2203014 16 1 Motor Bracket 5S2203015 17 4 Mounting Screws 5S2203016 18 1 Blade Spring 5S2203017 19 1 B...

Page 8: ...210575001 Rev A 1 08 8 of 8 www geelectrical com ...