To avoid risk of electrical shock, personal injury, or
death, disconnect power to unit before servicing.
Disassembly Procedures
23
WARNING
!
Loading
door
5. Maneuver loading door from washer cabinet top.
Loading
door
6. Remove screws securing right hinge and remove
loading door.
7. Reverse procedure to reassemble.
Agitator
1. Open loading door.
2. Remove agitator by placing hands under agitator
lip and pull upward, if agitator is stuck or
stubborn use agitator belt WX5X1326 under bottom
edge of agitator.
3. Using a rocking motion (side-to-side) carefully lift
agitator up off drive bell.
4. To reassemble place agitator on top of drive bell.
Slowly rotate agitator until fingers on underside of
agitator line up with large slots on drive bell.
5. A sharp blow on top of agitator, with the palm of
your hand, will force agitator down onto drive
bell, allowing fingers on underside of agitator to
lock under bottom edge of drive bell.
NOTE: Do not push agitator onto drive bell any
further than necessary.
Agitator, Drive Bell and Seal Assembly
NOTE: If water is present in washtub, remove water
before attempting to remove drive bell.
1. Remove agitator, see “Agitator” procedure.
2. Remove plug and
7
/
16
" bolt from top of drive bell.
3. Using care pry drive bell upward off transmission
shaft.
4. Remove old seal from hub assembly by:
a. Placing a flat bladed screwdriver between
bottom edge of seal and hub.
b. Using washtub bolts as a pry area, pop off
lower seal bead.
c. Grasping bottom of seal and pulling straight up
freeing upper seal bead.
Hex
nut
Hub
assembly
Hub
shoulder
Bronze
bearing
Washer
Transmission
output shaft
5. Clean all foreign material from seal mounting
area of hub assembly, bronze bearing and
washer.
6. Lubricate new seal with liquid soap or soapy
water to aid in assembly of seal onto hub.