10.3.2.1
Parameters of the Block Move Function
Input/
Output
Choices
Description
enable
flow
When the function is enabled, the block move is
performed.
I1 to I7
constant
I1 through I7 contain seven constant values.
ok
flow, none
The OK output is energized whenever the
function is enabled.
Q
I, Q, M, T, G, R, AI, AQ
For Word data: SA, SB,
SC
For Real data: R, AI, AQ
Output Q contains the first element of the moved
array. I1 is moved to Q.
10.3.2.2
Example
In the example, when the enabling input represented by the nickname FST_SCN is ON,
the Block Move function copies the input constants into memory locations %R0010–16.
FST_SCN
| |
BLKMV
INT
%R010
Q
I1
CONST
+32767
I2
CONST
-32768
I3
CONST
+00001
I4
CONST
+00002
I5
CONST
-00002
I6
CONST
-00001
I7
CONST
+00001
10.3.3
Data Move Functions Block Clear
The Block Clear function fills a specified block of data with zeros. When the function
receives power flow, it writes zeros into the memory location beginning at the reference
specified by IN. When the data to be cleared is from discrete memory (%I, %Q, %M, %
G, or %T), the transition information associated with the references is also cleared.
The function passes power to the right whenever power is received.
Word to be cleared
OK
Enable
BLK_
CLR
WORD
IN
150
GFK-1503E
VersaMax PLC User Manual
For public disclosure
Summary of Contents for VersaMax PLC
Page 16: ...Notes 16 GFK 1503E VersaMax PLC User Manual For public disclosure ...
Page 38: ...Notes 38 GFK 1503E VersaMax PLC User Manual For public disclosure ...
Page 50: ...Notes 50 GFK 1503E VersaMax PLC User Manual For public disclosure ...
Page 92: ...Notes 92 GFK 1503E VersaMax PLC User Manual For public disclosure ...
Page 112: ...Notes 112 GFK 1503E VersaMax PLC User Manual For public disclosure ...
Page 224: ...Notes 224 GFK 1503E VersaMax PLC User Manual For public disclosure ...
Page 292: ...Notes 292 GFK 1503E VersaMax PLC User Manual For public disclosure ...
Page 316: ...Notes 316 GFK 1503E VersaMax PLC User Manual For public disclosure ...
Page 317: ......