POWER SUPPLY

This downdraft vent must be supplied with 120V, 60 

Hz. and connected to an individual, properly grounded 

branch circuit, protected by a 15- or 20-ampere circuit 

breaker or time-delay fuse.
A properly grounded 3-prong receptacle should be 

located within reach of the vent’s two-foot power cord. 

•  Gas Cooktops

   If this vent is installed in combination with a GE or 

Monogram gas cooktop, it may operate from the same 

duplex outlet.

•  Electric Cooktops

   If this vent is installed in combination with a GE or 

Monogram electric cooktop, the vent must operate 

from a separate 120V outlet.

Locate the receptacle inside the cabinet on the right side 

wall (see illustration). The receptacle cannot be placed 

on the back of the cabinet wall where it may interfere 

with the downdraft plenum. 
The downdraft vent power cord is to be routed beneath 

the cooktop and routed away from heat generated by the 

cooktop.
Ensure that the cooktop is installed per manufacturer’s 

installation instructions.

IMPORTANT

(Please read carefully)

The power cord of this appliance is equipped with 

a three-prong (grounding) plug which mates with a 

standard three-prong grounding wall receptacle to 

minimize the possibility of electric shock. The customer 

should have the wall receptacle and circuit checked by 

a qualified electrician to make sure the receptacle is 

properly grounded and has correct polarity.

• 

 Where a standard two-prong wall receptacle is 

encountered, it is the personal responsibility and 

obligation of the customer to have it replaced with a 

properly grounded three-prong wall receptacle.

Do not, under any circumstances, cut or remove the 

third (ground) prong from the power cord.

Do not use an extension cord or adapter plug with this 

appliance. Follow National Electrical Code or prevailing 

local codes and ordinances.
Location of Rating Label: on front of chassis of vent 

system.

Locate the Gas or 

Electrical Connection Only 

Within the Shaded Area

DO NOT Locate 

Gas or Electrical 

Connections within 

this Area

34" (cutout width) for 36" models

28-1/2" (cutout width) for 30" models

29-1/2" 

12" 

Electrical 

Outlet 12" 

Above 

Cabinet 

Floor

Summary of Contents for UVB30

Page 1: ...e nuestro sitio de internet GEAppliances com VENT SYSTEM Downdraft 49 80777 1 07 17 GEA SAFETY INFORMATION 3 USING THE HOOD Downdraft Vent System 5 CARE AND CLEANING Downdraft Vent System 6 INSTALLATI...

Page 2: ...nto every GE Appliances product and we think you will too Among other things registration of your appliance ensures that we can deliver important product information and warranty details when you need...

Page 3: ...r responsibility and obligation to have an ungrounded outlet replaced with a properly grounded three prong outlet in accordance with the National Electrical Code Do not use an extension cord with this...

Page 4: ...servicing the unit It may be necessary to remove the vent system blower system in order to service components such as the blower motor or air vent mechanism Disconnect power to the cooktop and remove...

Page 5: ...r by pressing HIGHER or LOWER The blower if left on will automatically turn off when the vent is lowered NOTE For most convenient operation set the blower to the speed you use most often The blower wi...

Page 6: ...e Assistance and Accessories sections at the beginning of this manual Grease Filters The efficiency of your vent system depends on a clean filter Frequency of cleaning depends on the type of cooking y...

Page 7: ...t This appliance is equipped with a cord having a grounding wire with a grounding plug The plug must be plugged into an outlet that is property installed and grounded WARNING Improper grounding can re...

Page 8: ...Association NFPA the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electri...

Page 9: ...op is installed per manufacturer s installation instructions IMPORTANT Please read carefully The power cord of this appliance is equipped with a three prong grounding plug which mates with a standard...

Page 10: ...be located outside of the cabinet such as below the cabinet floor Contact us to purchase the Remote Blower Kit or to find the dealer nearest to you call the GE Appliances National Parts Center toll f...

Page 11: ...ocation confirm the clearances needed within the cabinet the exhaust vent direction and the alignment of the exhaust vent with the ducting If needed for clearance or duct hookup alignment reposition t...

Page 12: ...discharge A left or right 90 direction adjustment should be performed before dropping into the countertop opening To change to a left or right discharge Remove the 4 screws holding the blower and the...

Page 13: ...inet back wall is more than 4 1 2 false walls should be constructed inside the cabinet for securing the vent with the stabilizing brackets refer to Cutouts and Clearances under Installation Preparatio...

Page 14: ...oe space Peninsula or island Peninsula Outside wall cabinet NOTE PVC sewer pipe type PSM 12454 B Schedule 40 ASTM D1785 Wall Cap Concrete Slab 6 15 cm Dia PVC Sewer Pipe 6 15 cm Dia Metal Duct Pack ti...

Page 15: ...p cutout so that the back flange of the vent is sitting on top of the countertop C Secure the screws for the stabilizing brackets to the cabinet back and side walls D Confirm the vent system is plumb...

Page 16: ...ick adhesive wire clamp near the 1 2 dia hole and attach the loose wire with a wire tie Connect Wire Lead to Control Box Connect the mating wire ends Place the adhesive wire clamps provided near the m...

Page 17: ...ed into an outlet Plug the vent into a 120V power outlet The raise lower pad did not engage the lift motor Hold down the pad for a couple of seconds to activate the motor The circuit breaker may have...

Page 18: ...d in this Limited Warranty Any implied warranties including the implied warranties of merchantability or fitness for a particular purpose are limited to one year or the shortest period allowed by law...

Page 19: ...intenance experiences Refer to the Consumer Support page for phone numbers and website information The following products and more are available Accessories Parts Filter UVB30 WB02X10932 Filter UVB36...

Page 20: ...is still in effect You can purchase it on line anytime GE Appliances Services will still be there after your warranty expires In the US GEAppliances com ge service and support shop for extended servic...

Reviews: