March 2004
1-4
Installation
Mounting the UTX878
Electronics Enclosure
The standard Model UTX878 electronics package is housed in a
epoxy-coated aluminum weatherproof NEMA4X, IP67 enclosure
suitable for indoor or outdoor use. Figure 1-5 on page 1-11 shows the
outline and installation drawing. Refer to Chapter 7,
Specifications,
for the mounting dimensions and the weight of this enclosure.
Making the Electrical
Connections
This section contains instructions for making all the necessary
electrical connections to the Model UTX878 flow transmitter. Refer
to Figure 1-7 on page 1-13 for a complete wiring diagram.
!ATTENTION EUROPEAN CUSTOMERS!
To meet CE Mark requirements, all cables
must be installed as described in
Appendix B, CE Mark Compliance.
!WARNING!
Always disconnect the line power from the Model
UTX878 before removing the front cover.
Preparing the Unit
Before Making Electrical
Connections
Prepare the unit as described below before making any electrical
connections.
1.
Disconnect any previously wired power line from the unit.
2.
Remove the screws on the front cover.
3.
Install any required cable clamps on the appropriate conduit holes
on the bottom of the enclosure.
Proceed to the next section to make the desired wiring connections.
Summary of Contents for UTX878 Ultrasonic
Page 2: ...iii March 2004 The UTX878 Flow Transmitter and Transducers ...
Page 8: ...Chapter 1 ...
Page 20: ...March 2004 Installation 1 11 Figure 1 5 UTX878 Outline and Installation Dwg 712 1196 rev 2 ...
Page 22: ...March 2004 Installation 1 13 Figure 1 7 UTX878 Wiring Diagram Dwg 702 528 rev 2 ...
Page 23: ...Chapter 2 ...
Page 45: ...Chapter 3 ...
Page 52: ...Chapter 4 ...
Page 60: ...Chapter 5 ...
Page 65: ...Chapter 6 ...
Page 75: ...Chapter 7 ...
Page 80: ...Appendix A ...
Page 85: ...Appendix B ...
Page 86: ...CE Mark Compliance Introduction B 1 EMC Compliance B 1 ...
Page 88: ...Appendix C ...
Page 89: ...Data Records Site Data C 1 ...
Page 93: ...Appendix D ...
Page 94: ...Service Record Introduction D 1 Data Entry D 1 Diagnostic Parameters D 3 ...