4
31-1000617 Rev. 0
Installation Instructions
8
FINALIZE INSTALLATION
Ŷ
Re-install side panel using the screws removed
in step 1.
Ŷ
Re-install unit into built-in or free-standing
location. ENSURE THAT NO KINKS OCCUR
IN WATER INLET OR DRAIN TUBING. Double-
check for leaks!
Ŷ
Restore potable water supply and restart the
unit. Check unit to ensure proper operation and
to allow a final check for leaks of any kind.
7
CHECK PUMP OPERATION
Ŷ
Restore power to the unit.
Ŷ
With the unit still in standby mode (ice making
not on) , pour several quarts of water into the
bin. The drain pump should turn on and pump
the water out of the bin, cycling on and off
several times during the process. Pump cycling
is normal since the pump-out rate of the drain
pump is greater than the rate of drain through
the bin.
Ŷ
While the pump is discharging water,
THOROUGHLY CHECK THE ENTIRE DRAIN
SYSTEM FOR LEAKS.
INSTALLING PUMP KIT
(Cont.)
6
CONNECT DRAIN PUMP TO ICE
MACHINE (Cont.)
Ŷ
Locate the pressure sensor connector in the ice
machine behing the 2 holes in the flange shown
in the diagram below. Insert the connector into the
pressure sensor housing.
Attach the pressure switch assembly in the 3 holes
of the flange of the ice machine, as shown, using
the screw provided with the kit.
Ŷ
Thread the drain hose into the round hole in the
back of the ice machine case and attach to the
nozzle on the top of the drain pump using the large
metal clamp.
6
CONNECT DRAIN PUMP TO ICE
MACHINE (Cont.)
Ŷ
IMPORTANT
Ground the pump to
the machine cabinet using the green ground wire
and screw.
The grounding hole is marked with a
grounding symbol.
Pressure Sensor
Connector from
Ice Machine
Pressure Switch
Assy from Drain
Pump
Pressure Switch Assembly
Screw
Back of Ice Maker
Drain Hose
Drain Hose
Nozzle
Large Metal Clamp