• Supports Tetra miniMAX, Tetra MAX, Tetra PowerMAX,
Tetra PowerStrip and Tetra miniStrip LED lighting systems
• Class 2 wiring per NEC Article 725 (SELV)
• IP66 rated: wet location rated
• M20 Thread
(GEPS12W-60M)
Tetra
®
LED Systems Power Supply
12
Volt
GE
Lighting Solutions
Installation Guide
imagination at work
Power Supply Features
Power Supply Installation
1
Power supply
Conduit
Power supply
input wires
AC Line
Run AC line through conduit and
attach conduit to outdoor-rated
enclosure. Attach power supply to
enclosure.
3
Brown (-)
Blue (+)
Connect the AC line to the brown
(line) and blue (neutral) input wires of
the power supply using 18-14 AWG
(0.82-2.08 mm
2
) twist-on wire
connectors. Properly ground (green
wire with yellow stripe) power supply
in accordance with National Electric
Code (NEC) Article 600.
Connect the red stripe wire (+) of the
LED strip to the red wire (+) of the
power supply. Connect the white
wire (-) of the LED strip to the black
wire (-) of the power supply.
2
To power supply
Red (+)
Red stripe (+)
White (-)
Black (-)
NOTE:
All electrical connections
should be made within the letter.
RISK OF ELECTRIC SHOCK:
• Disconnect power at fuse box or circuit breaker before servicing or
installing product.
• Properly ground Tetra
®
power supply.
RISK OF FIRE:
• Use only approved wire for input/output connection.
Minimum size 18 AWG (0.82 mm
2
)
• Follow all local codes.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation électrique à la boîte de fusibles ou au
disjoncteur avant l’entretien ou l’installation du produit.
• Assurez-vous de correctement mettre à terre l’alimentation
électrique Tetra
®
.
RISQUES D’INCENDIE
• N’utilisez que des fils approuvés pour les entrées/sorties de
connexion. Taille minimum 18 AWG (0.82 mm
2
).
• Respectez tous les codes locaux.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING/AVERTISSEMENT
Green with