GE Tetra PowerStrip DS Installation Manual Download Page 3

3

To Power Supply 

Red (+)

Red stripe (+)

White (-)

Power Supply

To LED System

Red (+)

Black or blue (-)

Run a wire from the power supply to inside the sign and 

connect to the first module on the strip. 
NOTE: Exceeding maximum load will cause the power 
supply to shut down. If overload occurs, remove excess 
load, recycle the input power to restart the power supply.

3

Connect the red stripe wire (+) of the LED system to the 

red wire (+) of the power supply. Connect the white wire (-) 

of the LED system to the black or blue wire (-) of the power 

supply.

4

Retrofit Instructions

1.    (Existing Signs Only) Prior to installation, survey the site for information regarding power and accessibility inside and outside the building.  Ensure   

 

that the branch circuit supplying the existing transformer or ballast will be within the voltage ratings of the new LED power supply, and have  

 

 

a current rating not exceeding 20A, or that permitted by applicable local, state, or country electrical codes (whichever is less).   

2.   (Existing Signs Only) Remove the existing lighting equipment to be replaced, such as neon tubing or fluorescent tubes; and associated   

 

transformers and ballasts.  Care should be taken not to break the existing neon or fluorescent tubes.  

 NOTE:

 Follow all federal and local regulations when disposing of neon tubing, fluorescent tubes, transformers and ballasts.

3.   (Existing Signs Only)  If removal of the existing lighting equipment eliminates the disconnect switch, as required by applicable local, state, or 

 

country electrical codes; a new disconnect switch must be installed.

4.   (Existing Signs Only) Repair and seal any unused openings in the electrical enclosure. Openings greater than 12.7-mm (1/2-in) diameter require a  

 

metal patch secured by screws or rivets and caulked with non-hardening caulk. Smaller openings may be sealed with non-hardening caulk.

5.   Using the layout guidelines above, determine required number of LED modules required to illuminate the sign.
6.   A Tetra

®

 24VDC Class 2 Power Supply, as listed below, must be used with this retrofit kit.  Using the Maximum Loading chart below, determine the   

 

number of Tetra

®

 Class 2 Power Supplies required to power the number of LED modules required to illuminate the sign, so as not to overload  

 

 

the Tetra

®

 Class 2 Power Supply chosen.

7.   Follow the instructions above to properly mount the LED modules. 
8.   Connect the DC output of the power supply to the LED modules using the Electrical Connections instructions above.
9.   Connect the power unit to the supply in accordance with the applicable local, state, and country electrical codes, and the instructions found in the  

 

power supply installation guide.

10. If required, the disconnect switch shall be installed by qualified personnel, in accordance with applicable  local, state, and country electrical codes.

Connect modules using twist-on wire connectors or 

in-line (IDC) connectors. Join white wires together and 

red striped wires together. 
NOTE:

 Additional supply wire may be necessary to 

bridge electrical connections.

Cap all exposed wires with appropriate end caps 

or apply electric grade (non-corrosive) silicone for 

additional weather protection.

1

2

Electrical Connections

Red stripe (+)

White (-)

Black or blue (-) 

NOTE: Do not use connectors pre-filled with silicone grease/mineral base protective grease or use silicone grease to seal connections.

NOTE: All electrical connections should be suitably 
protected from mechanical damage and the environment. 
Seal all connections in locations that may be exposed to 
water with electrical grade RTV silicone.

Summary of Contents for Tetra PowerStrip DS

Page 1: ...PARTS REQUIRED BY THE INSTRUCTIONS ARE PRESENT TROUSSE DE CONVERSION À DEL POUR LA MODERNISATION DES ENSEIGNES À UTILISER CONFORMÉMENT AU GUIDE D INSTALLATION WARNING AVERTISSEMENT RISK OF ELECTRIC SHOCK Turn power off before inspection installation or removal Properly ground GE power supply enclosure RISK OF FIRE Use only UL approved wire for input output connections Minimum size 18 AWG 0 82mm2 F...

Page 2: ...e modules evenly spaced apart Place the Tetra modules on the Mounting Rail and secure into lip with a self tapping 6 M3 screw or 1 8 inch 3 175 mm rivet Or mount using the alternative clip and extender rod configuration Components Alternative clip and extender rod Electrical grade RTV silicone Example electrical grade RTV silicones include Momentive RTV 6700 Series Silicone Rubber Adhesive Sealant...

Page 3: ...m 1 2 in diameter require a metal patch secured by screws or rivets and caulked with non hardening caulk Smaller openings may be sealed with non hardening caulk 5 Using the layout guidelines above determine required number of LED modules required to illuminate the sign 6 A Tetra 24VDC Class 2 Power Supply as listed below must be used with this retrofit kit Using the Maximum Loading chart below det...

Page 4: ...6 m 80W Power Supply 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m 100W Power Supply 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m 180W Power Supply 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m 300W Power Supply 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m Maximum Loading per Tetra 24 VDC Class 2 Power Supply SKU Rating 25W Power Supply Note Load shall not exceed 1 04A 80W Dimmin...

Reviews: