Components:

5

UL approved 18 AWG (0.82 mm

2

)    

supply wire

UL approved 22-14 AWG 
(0.33-2.08 mm

2

) wire connectors 

or 22-18 AWG (0.33-0.82 mm

2

in-line/IDC connectors

#6 or #8 (M3 or M4) screws or 
1/8 inch (3.2 mm) rivets

Power Supply (GEPS12-20, 
GEPS12-60  or GEPS12-60U)

Tetra

®

 miniMAX LED modules

Components

imagination at work

Tetra

®

 

miniMAX

LED Lighting System

Symptom

Solution

All letters are OFF

• Check AC input connetion and/or check circuit breaker.
• Check wire connection(s) at the Tetra

® 

LED System and power supply for improper    

  termination(s) or short circuits. Properly terminate or replace the wire connection(s).
• Check that connections are the red striped wire (+) of the LED strip to the red wire (+) of the  
  power supply and the white wire (-) of the LED strip to the black wire (-) of the power supply.

Some LEDs appear dim

• Ensure the overall length of the Tetra

® 

LED System does not exceed the maximum load.

• Ensure the length of supply wire is equal to or below the recommended remote mounting  
  distance.

Some of the letters are 
not illuminated

• Check wire connection(s) at the Tetra

® 

LED System and power supply for improper    

  termination(s) or short circuits. Properly terminate or replace the wire connection(s).
• Check that connections are the red striped wire (+) of the LED strip to the red wire (+) of the  
  power supply and the white wire (-) of the LED strip to the black wire (-) of the power supply.

Shadows

• Re-route supply wire and secure to the back of the can with silicone. Adjust wire  

 

  connector orientation so that it does not cover any LEDs.
• Adjust LED layout to ensure uniformity of illumination on the face of the letter.

Troubleshooting

SIGN055-R082409

(GEWHMMS5, GEWWMMS5, GERDMMS5, GEGLMMS5, GEBLMMS5)

RISK OF ELECTRIC SHOCK:

• Turn power OFF before inspection, installation    

  or removal.

• Properly ground Tetra Power Supply enclosure.

RISK OF FIRE:

• Follow all NEC and local codes.

• Use only UL approved wire for input/output  

 

  connections. Minimum size 18 AWG (0.82 mm

2

)

WARNING!

BEFORE YOU BEGIN

Read these instructions completely and carefully.

Prepare Electrical Wiring

Electrical Requirements

•  Do not use in wet locations.
•  The grounding and bonding of the LED Driver shall be
  done in accordance with National Electric Code (NEC)
  

  Article 600.
•  Follow all National Electric Codes (NEC) and local codes.

Risk of electrical shock. Disconnect power before servicing or 

installing product. 

Risque de choc électrique. Couper l’alimentation avant 

le dépannage ou avant l’installation du produit.

WARNING / AVERTISSMENT

6180 Halle Drive • Valley View, Ohio 44125-4635 • USA
P: 216.606.6555 • F: 216.606.6599 • www.lumination.com • [email protected]

Lumination, LLC is a subsidiary of the General Electric Company. Tetra is a trademark of Lumination, LLC. The GE brand, logo, and ecomagination are trademarks of the General Electric Company. 
© 2009 Lumination, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.

For customer service & technical support, contact:
1-888-MY-GE-LED      (1.888.694.3533)

Tips

•  Tetra LED systems are rated for damp location use by UL, and should be protected from direct exposure to moisture  

  (i.e., rain & snow). 
•  For optimal light uniformity in halo-lit applications the Tetra LED modules should be mounted on UL recognized plastic  

  and the light output from the Tetra LED system should be directed back into the sign enclosure. This will allow for  

 

  uniform backlighting of the sign and will provide simple mounting for the Tetra LED system. 
•  When mounting LED modules for halo-lit applications the clear acrylic should be recessed into the body of the sign or  

  a bead of silicone should be applied to provide a barrier against the elements.

•  A best practice for the supply wire at the point at which it is brought into the sign is to have a drip loop on the inside of  

  the letter to keep water from collecting on the Tetra LED strip.

IP66 rated: separate enclosure required for outdoor use, UL damp location rated

Conforms to the following standards:

Summary of Contents for Tetra miniMAX

Page 1: ...nly UL approved wire for input output connections Minimum size 18 AWG 0 82 mm2 WARNING BEFORE YOU BEGIN Read these instructions completely and carefully Prepare Electrical Wiring Electrical Requirements Do not use in wet locations The grounding and bonding of the LED Driver shall be done in accordance with National Electric Code NEC Article 600 Follow all National Electric Codes NEC and local code...

Page 2: ... applications LED modules should be mounted on UL recognized clear acrylic or polycarbonate The light output from the LED system should be directed back into the sign enclosure This will allow for uniform backlighting of the sign and will provide simple mounting and protection against moisture Drill a 1 4 inch 6 4 mm hole near the LED strip and grommet the hole for supply wire access Use rivets or...

Page 3: ... applications LED modules should be mounted on UL recognized clear acrylic or polycarbonate The light output from the LED system should be directed back into the sign enclosure This will allow for uniform backlighting of the sign and will provide simple mounting and protection against moisture Drill a 1 4 inch 6 4 mm hole near the LED strip and grommet the hole for supply wire access Use rivets or...

Page 4: ...nly UL approved wire for input output connections Minimum size 18 AWG 0 82 mm2 WARNING BEFORE YOU BEGIN Read these instructions completely and carefully Prepare Electrical Wiring Electrical Requirements Do not use in wet locations The grounding and bonding of the LED Driver shall be done in accordance with National Electric Code NEC Article 600 Follow all National Electric Codes NEC and local code...

Reviews: