Run a wire from the LED power supply to the LED module 

and connect. 
NOTE:

 Must be used with Tetra® 24 Volt Power Supplies.

NOTE:

 Refer to Maximum Loading & Remote Mounting 

Specifications

 on page 4.

3

LED 

Power 

Supply

To Tetra LED System

Red (+)

Black or blue (-)

To LED 

power 

supply 

Red (+)

Black or 

blue (-)

Red Stripe (+)

Connect the red stripe wire (+) of the LED strip to the red 

wire (+) of the power supply.  Connect the white wire (-) 

of the LED strip to the black or blue wire (-) of the LED 

power supply.
NOTE:

  All electrical connections should be suitably 

protected from mechanical damage and the 

environment. Seal all connections in wet locations with 

electrical grade RTV silicone.

4

White (-)

Seal all connections in wet locations 

with electrical grade RTV silicone

OPTIONAL 
A Weather Box (GEXNWB2) may be used to house 
and seal Class 2 connections as described below: 
A) Insert wire connectors into weather box. Fill 

with electrical grade silicone and close box. 
B) Secure the weather box using a #6 or #8 (M2 

or M3) screw.

Weather box 

can be painted

Light engine

A

B

Retrofit Instructions

1.   (Existing Signs Only) Prior to installation, survey the site for information regarding power and accessibility inside and outside the building.  Ensure 

that the branch circuit supplying the existing transformer or ballast will be within the voltage ratings of the new LED power supply, and have a 

current rating not exceeding 20A, or that permitted by applicable local, state, or country electrical codes (whichever is less). 

2.   (Existing Signs Only) Remove the existing lighting equipment to be replaced, such as neon tubing or fluorescent tubes; and associated 

transformers and ballasts. Care should be taken not to break the existing neon or fluorescent tubes.  NOTE: Follow all federal and local regulations 

when disposing of neon tubing, fluorescent tubes, transformers and ballasts.

3.   (Existing Signs Only)  If removal of the existing lighting equipment eliminates the disconnect switch, as required by applicable local, state, or 

country electrical codes; a new disconnect switch must be installed.

4.   (Existing Signs Only) Repair and seal any unused openings in the electrical enclosure. Openings greater than 12.7-mm (1/2-in) diameter require a 

metal patch secured by screws or rivets and caulked with non-hardening caulk. Smaller openings may be sealed with non-hardening caulk.

5.   (Existing Signs Only) A clean and dry mounting surface ensures optimum adhesion if the self-adhesive method of mounting is chosen.  Follow 

the manufacturer’s directions when using a non-oil based solvent, such as rubbing alcohol to clean the surface area where you intend to mount 

the module.  Before installing, ensure the surface is dry.

6.  Using the layout guidelines above, determine required number of LED modules required to illuminate the sign.
7.  A Tetra

®

 24VDC Class 2 Power Supply, as listed below, must be used with this retrofit kit. Using the Maximum Loading chart below, determine the 

number of Tetra

®

 Class 2 Power Supplies required to power the number of LED modules required to illuminate the sign, so as not to overload the 

Tetra

®

 Class 2 Power Supply chosen.

8.  Follow the instructions above to properly mount the LED modules. 
9.  Connect the DC output of the power supply to the LED modules using the Electrical Connections instructions above.
10.  Connect the power unit to the supply in accordance with the applicable local, state, and country electrical codes, and the instructions found in the 

power supply installation guide.

11.  If required, the disconnect switch shall be installed by qualified personnel, in accordance with applicable  local, state, and country electrical codes.

FOR UL ONLY

4

Summary of Contents for Tetra miniMAX MS

Page 1: ...s instrucciones de instalación y la información sobre seguridad puede encontrarse en la siguiente ubicación https products currentbyge com eu ET Eestikeelse paigaldusjuhendi ja ohutusnñuded leiate aadressilt https products currentbyge com eu FI Asennusohjeiden ja turvallisuustietojen suomenkielinen versio löytyy seuraavasta paikasta https products currentbyge com eu FR La version française des ins...

Page 2: ...eut impliquer le perçage ou le poinçonnage de trous dans la structure du panneau Vérifiez le câblage et les composants inclus pour éviter d endommager le câblage et les composants électriques Ne pas faire ou modifier les trous ouverts dans une enceinte de câblage ou de composants électriques pendant l installation de cet équipement de remplacement DEL This device complies with part 15 of the FCC R...

Page 3: ...urfaces with a 50 50 mixture of isopropyl alcohol IPA and water and let dry 1 Layout Modules Remove tape backing and stick LED modules into place When using tape apply approximately 15 psi pressure on the module avoid the lens dome surface for 5 seconds full bonding strength after 24 hours Continue until you have reached the end of the strip 3 Do not press lens Electrical Connections NOTE Do not u...

Page 4: ...NOTE Follow all federal and local regulations when disposing of neon tubing fluorescent tubes transformers and ballasts 3 Existing Signs Only If removal of the existing lighting equipment eliminates the disconnect switch as required by applicable local state or country electrical codes a new disconnect switch must be installed 4 Existing Signs Only Repair and seal any unused openings in the electr...

Page 5: ... the supply wire at the point at which it is brought into the sign is to have a drip loop on the inside of the letter to keep water from collecting on the Tetra LED strip These products are not required to be enclosed or protected from weather Troubleshooting Symptom Solution All letters are OFF Check AC input connection and or check circuit breaker Check wire connection s at the Tetra LED System ...

Reviews: