•  Tetra

®

 LED systems are rated for damp location use by UL, and should be protected from direct exposure to moisture (i.e., rain & snow).

•  For optimal light uniformity in halo-lit applications the Tetra

®

 LED modules should be mounted on UL recognized plastic and the light output 

from the Tetra

®

 LED system should be directed back into the sign enclosure. This will allow for uniform backlighting of the sign and will 

provide simple mounting for the Tetra

®

 LED system.

•  When mounting LED modules for halo-lit applications the clear acrylic should be recessed into the body of the sign or a bead of silicone 

should be applied to provide a barrier against the elements.

•  A best practice for the supply wire at the point at which it is brought into the sign is to have a drip loop on the inside of the letter to keep 

water from collecting on the Tetra

®

 LED strip.

Maximum Loading per Tetra 12 VDC Power Supply

Maximum Remote Mounting Distance

SKU

Rating

20W Power Supply 

Note: Load shall not exceed 

1.6A

60W Power Supply 

Note: Load shall not exceed 5A

180W Power Supply 

Note: Load shall not exceed 

5A per each (of 3) output channels

GEMS71-1, GEMS50-1, 

GEMS41-1, GEMS32-1,

GEMSRD-1, GEMSBL-1

12VDC, 32mA/module

0.384W/module

50 modules/20 ft. (6.10 m)

150 modules/60 ft. (18.29 m)

150 modules/60 ft. (18.29 m) 

per output channel 

450 modules/180 ft. (54.88 m) 

per power supply

GEMSGL-1

12VDC, 26mA/module 

0.312W/module

18 AWG/0.82 mm

Supply Wire

16 AWG/1.31 mm

Supply Wire

14 AWG/2.08 mm

Supply Wire

12 AWG/3.31 mm

Supply Wire

20W Power Supply

120 ft./36.6 m

-

-

-

60W Power Supply

30 ft./9.1 m

50 ft./15.2 m

80 ft./24.4 m

120 ft./36.6 m

180W Power Supply

30 ft./9.1 m

50 ft./15.2 m

80 ft./24.4 m

120 ft./36.6 m

NOTE: For linear runs longer than 40ft, center connection to the LED strip is recommended to minimize voltage drop.

Troubleshooting

Symptom

Solution

All letters are OFF

•  Check AC input connection and/or check circuit breaker.

•  Check wire connection(s) at the Tetra

® 

LED System and power supply for improper termination(s) or short 

circuits. Properly terminate or replace the wire connection(s).

•  Check that connections are the red striped wire (+) of the LED strip to the red wire (+) of the power supply and the 

white wire (-) of the LED strip to the black or blue wire (-) of the power supply.

Some LEDs 

appear dim

•  Ensure the overall length of the Tetra

® 

LED System does not exceed the maximum load.

•  Ensure the length of supply wire is equal to or below the recommended remote mounting distance.

Some of the letters

are not illuminated

•  Check wire connection(s) at the Tetra

® 

LED System and power supply for improper termination(s) or short 

circuits. Properly terminate or replace the wire connection(s).

•  Check that connections are the red striped wire (+) of the LED strip to the red wire (+) of the power supply and 

the white wire (-) of the LED strip to the black or blue wire (-) of the power supply.

Shadows

•  Re-route supply wire and secure to the back of the can with silicone. Adjust wire connector orientation so that it 

does not cover any LEDs.

•  Adjust LED layout to ensure uniformity of illumination on the face of the letter.

Summary of Contents for Tetra miniMAX MS GEMS71-1

Page 1: ...iji https products gecurrent com eu HU A telepítési útmutató és a biztnosági információk magyar nyelvű változata az alábbi címen található https products gecurrent com eu IT La versione italiana del manuale di installazione e sicurezza può essere reperita nella seguente sezione https products gecurrent com eu LT Lietuvišką diegimo instrukcijos ir saugos informacijos versiją galima rasti šioje viet...

Page 2: ...OU DE CHOC ÉLECTRIQUE L installation de l équipement de remplacement DEL exige Ia connaissance des systèmes électriques pour enseignes Si non qualifié ne tentez pas d installation Veuillez contacter un électricien qualifié Risque d incendie ou de choc électrique Installez cet ensemble seulement dans des enseignes hôtes qui ont été identifiés dans les instructions d installation et dont la capacité...

Page 3: ... 2 08 mm2 wire connectors or 22 18 AWG 0 33 0 82 mm2 in line IDC connectors 6 or 8 M3 or M4 screws 1 8 inch 3 2 mm rivets or electronic grade silicone or equivalent Tetra 12 Volt Power Supply Tetra miniMAX MS LED modules Components Layout Modules Drill a 1 4 inch 6 4 mm hole near the LED strip and grommet the hole for supply wire access Clean and remove all debris from the inside of the channel le...

Page 4: ...val of the existing lighting equipment eliminates the disconnect switch as required by applicable local state or country electrical codes a new disconnect switch must be installed 4 Existing Signs Only Repair and seal any unused openings in the electrical enclosure Openings greater than 12 7 mm 1 2 in diameter require a metal patch secured by screws or rivets and caulked with non hardening caulk S...

Page 5: ...les 60 ft 18 29 m 150 modules 60 ft 18 29 m per output channel 450 modules 180 ft 54 88 m per power supply GEMSGL 1 12VDC 26mA module 0 312W module 18 AWG 0 82 mm2 Supply Wire 16 AWG 1 31 mm2 Supply Wire 14 AWG 2 08 mm2 Supply Wire 12 AWG 3 31 mm2 Supply Wire 20W Power Supply 120 ft 36 6 m 60W Power Supply 30 ft 9 1 m 50 ft 15 2 m 80 ft 24 4 m 120 ft 36 6 m 180W Power Supply 30 ft 9 1 m 50 ft 15 2...

Reviews: