Power Supply Features

(GEPS24-300U-GL)

• Supports Tetra PowerStrip, Tetra MiniStrip, Tetra EdgeStrip,

  Tetra Contour, Contour LS, and Line Fit Light lighting systems

• UL: Class 2 wiring per NEC Article 725.

• Limited to use in dry and damp locations.

• The suitability of rain enclosure shall be determined if 

  intended for wet location.

• Minimum 5 cm (2 in.) spacing from heat producing 

  components required.

• Minimum 4 to side and 1 in. spacing in compartment 

  surrounding component required.

• Three 96 watt output banks.

Tetra

®

 

LED Systems Power Supply

GE

Lighting Solutions

Installation Guide

24

Volt

 WARNING/AVERTISSEMENT

RISK OF ELECTRIC SHOCK
• Disconnect power at fuse box or circuit breaker before servicing or 

   installing product.
• Properly ground Tetra

®

 power supply.

RISK OF FIRE
• Use only Tetra

®

 supply wire to make connection from Tetra

®

 

   power supply to Tetra

®

 LED strip.

• Use only approved wire for input/output connection. Minimum size 

   18 AWG (0.82 mm

2

)

• Follow all local codes.

RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation électrique à la boîte de fusibles ou au disjoncteur 

   avant l’entretien ou l’installation du produit.
• Assurez-vous de correctement mettre à terre l’alimentation 
   électrique Tetra

®

.

RISQUES D’INCENDIE

®

 pour faire la connexion   

   entre l’alimentation Tetra

®

 et la bande DEL Tetra

®

.

   Taille minimum 18 AWG (0.82 mm

2

).

• Respectez tous les codes locaux.
• Avrisques d’incendie ou de choc lectriques. Ne pas interconnecter les  

  bornes de sortie.

BEFORE YOU BEGIN

Read these instructions completely and carefully.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, 

and (2) this device must accept any interference received, including interference that may cause undesired operation.

Note:

 This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are 

designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment 

generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful 

interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will 

be required to correct the interference at his own expense.
This Class [A] RFLD complies with the Canadian standard ICES-003. Ce DEFR de la classe [A] est conforme à la NMB-003 du Canada. 

Reviews: