Electrical Grade Silicone

3/8 in. (10mm) gap

Planning

For planning the layout, measure the perimeter of the building 

and divide by 8 ft. (2.44m) to determine the required quantity 

of Tetra Contour LS systems. See table below for guidelines 

about cutting resolution. For seamless designs, accessories are 

available for straight runs and 90 degree corners.

NOTE:

 Do not use more than one suffix code for each respective 

application, as mixing suffix codes may result in appearance 

variation. Suffix code can be found on the packaging label.

CAUTION

Risk of damage. Must use electrical grade silicone.

1

If it is necessary to cut the Tetra Contour LS for a better fit, 

refer to the Cutting Resolution table above.

2

If Tetra Contour LS sections are cut, apply electrical grade 

silicone to exposed cut and attach end cap.

Cutting Resolution Table

SKU

Color

Cutting Resolution

GEXNLRD-1

Red

8 inches (203 mm)

GEXNLGL-1

Green

8 inches (203 mm)

GEXNLBL-1

Blue

8 inches (203 mm)

GEXNL65-1

White

8 inches (203 mm)

GEXNL32-1

Warm White

8 inches (203 mm)

 Space mounting clips 

18 inches (457mm) apart

Attaching Contour Sections

2

1

Starting from one end, attach the Tetra Contour LS to the

mounting clips. Secure light guide by twisting tie-wire 

around the mounting clip and light guide.
NOTE:

 Wires can be concealed by tucking wires between 

mounting clips and Tetra Contour LS system.  

Install one mounting clip at each end and then a minimum 

of one mounting clip every 18 inches (457mm).
NOTE:

 Standard neon mounting hardware can also be used.

NOTE:

 Tetra Contour LS is intended for straight runs. 

Continue attaching all the sections to the remaining 

mounting clips, leaving a 3/8 inch (10mm) gap between 

sections to allow for expansion or contraction.

3

4

Plug together all adjacent Tetra Contour LS sections and 

tuck wires behind.

Example electrical grade silicones include: Momentive RTV 6700 Series Silicone Rubber Adhesive Sealant, Momentive White 

Blanc RTV 162 Silicone Rubber Adhesive Sealant-Electrical Grade, Dow Corning 3140 - Non-Corrosive Flowable (clear), Dow 

Corning 3145 - Non-Corrosive Nonflowable (clear or gray) & Dow Corning RTV 748 Non-Corrosive Sealant-White.

Summary of Contents for Tetra Contour LS Series

Page 1: ...le protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which cas...

Page 2: ... 1 White 8 inches 203 mm GEXNL32 1 Warm White 8 inches 203 mm Space mounting clips 18 inches 457mm apart Attaching Contour Sections 2 1 Starting from one end attach the Tetra Contour LS to the mounting clips Secure light guide by twisting tie wire around the mounting clip and light guide NOTE Wires can be concealed by tucking wires between mounting clips and Tetra Contour LS system Install one mou...

Page 3: ...or removal 3 Using twist on wire connectors connect the white wire with red stripe from the LED strip to the red wire of the power supply Connect the white wire from the LED strip to the black or blue wire of the power supply NOTE Grounding and bonding must be done in accordance with National Electrical Code Article 600 See power supply instructions White with red stripe Red White Black or blue To...

Page 4: ... AWG 2 08 mm2 Supply Wire 12 AWG 3 31 mm2 Supply Wire 20W Power Supply 20 ft 6 1 m 80W Power Supply 20 ft 6 1 m 30 ft 9 1 m 50 ft 15 2 m 86 ft 26 1 m 100W Power Supply 20 ft 6 1 m 30 ft 9 1 m 50 ft 15 2 m 86 ft 26 1 m 180W Power Supply 20 ft 6 1 m 30 ft 9 1 m 50 ft 15 2 m 86 ft 26 1 m Symptom Solution All LEDs are OFF Check AC input connection and or check circuit breaker Check wire connection s a...

Reviews: