38
Flash recovery system
Should the normal upgrade procedure fail or the system fail to boot up, the Flash recovery system will
automatically start to give you a chance to restore normal system functionality.
Flash recovery over the Ethernet
To restore system functionality using Flash recovery over the Ethernet, do the following:
1. Launch your browser software.
2. Enter the IP address of the SymNet1 in the address field of the browser and enter the username/
password.
3. The
Recovery
page (
) appears.
Figure 28. Recovery page
4. Click
Browse
and select the normal system bin file. Click
Send file
.
5. Click the
Confirm
and
Reboot
buttons to restart the unit.
6. The unit should reboot to normal operation.