DSKS433EB
GE Spacemaker
®
Stationary Dryer
Dimensions and Installation Information (in inches)
For complete information, see installation instructions packed with your dryer.
Ducting Materials:
For best performance, this dryer should be vented with 4" diameter all rigid metal
exhaust duct. If “all rigid metal” duct cannot be used, then “flexible all metal” venting can
be used, but it will reduce the maximum recommended duct length.
Exhaust Length Calculation:
1. Determine the number of 90° turns needed for your installation. If you exhaust to the
side or bottom of dryer, add one turn.
2. The maximum length of 4' rigid (aluminum or galvanized) duct which can be tolerated
is shown in the table. The maximum length for flexible ducts are less than for
rigid duct.
A turn of 45° or less may be ignored. Two 45° turns within the duct length should be
treated as a 90° elbow. A turn over 45° should be treated as a 90° elbow.
Exhausting the dryer to the outside is strongly recommended
to prevent large
amounts of moisture and lint from being blown into the room. Gas dryers or any dryer
located in a closet
must
be exhausted to the outside.
Caution:
For personal safety do not terminate exhaust into a chimney, under any
enclosed house floor (crawl space), or into an attic, since the accumulated lint could
create a fire hazard or moisture could cause damage. Never terminate the exhaust into
a common duct or plenum with a kitchen exhaust, since the combination of lint and
grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird
nesting, etc. The wall cap must also be located at least 12" above the ground or any
other obstruction with the opening pointed down.
Other terminations, such as louvered wall boxes, are acceptable provided they are
equivalent to a 4" opening dampered wall cap.
Dryer Note:
Dryer wall outlet must be located within 36" of service
cord entry and accessible when dryer is mounted in position.
DSKS433EBWW
80
100
10
90
OFF
OFF
60
50
40
30
20
70
cool down
PERM. PRESS & DEL
ICATES CYCLE
*PREFERRED
REGULAR SETTING
T I M E D CYC L E
PUSH TO START
AU TO
R EG U L A R
TEMPERATURE
REGULAR
(HIGH HEAT)
PERM PRESS
(MED. HEAT)
DELICATES
(LOW HEAT)
FLUFF
(NO HEAT)
NORMAL DRY
*
OFF
cool down
cool
down
EXTRA DRY
*NORMAL DRY
EXTRA DRY
33-1/4
24-1/2
23-7/8