REQUIRED TOOLS AND ACCESSORIES 
FOR INSTALLATION

2 Adjustable wrenches

Pipe cutter or hacksaw

File

Emery paper

Screwdriver

Additional installation parts may be required:

2 fittings to connect household plumbing to 1

female

NPT threads on filter housing. Installation Kit available
to connect to 3/4

copper plumbing:

– GE Part/Retail Part (HDKIT)

(Not performance tested or certified by NSF.)

UL Approved grounding clamps and 6-gauge copper
grounding wire—Installation Kit available:
– GE Part/Retail Part (HDKIT)

(Not performance tested or certified by NSF.)

Mounting Bracket (HDBRKT)

Teflon Tape

Sump Wrench
– Retail Part (HDWRNCH)
– GE Parts (WX5X3002)

Optional accessories are available (Visa, MasterCard or Discover cards
accepted) by visiting our Website at www.GEAppliances.com or from
Parts and Accessories, call 800.626.2002 (U.S.) or 800.663.6060 (Canada).

CONTENTS INCLUDED WITH PRODUCT

Filter housing and head

Product literature

1

GE Smar tWater

INSTALLATION INSTRUCTIONS

Heavy Duty Water Filtration System—GXWH30C (filters not included)

SAFETY PRECAUTIONS

Check with your state and local public works department
for plumbing and sanitation codes. You must follow these
guidelines as you install the Heavy Duty Water Filtration
System. Using a qualified installer is recommended.

Be sure the water supply conforms with the 

Performance

Data

. If the water supply conditions are unknown, contact

your municipal water company. 

WARNING:

Do not use with water that is

microbiologically unsafe or of unknown quality without
adequate disinfection before or after the system. 

It is highly recommended that a water shut-off valve be
placed directly upstream of your household filter.

Check with your local public works department for plumbing
codes. You must follow their guides as you install the 
Heavy Duty Water Filtration System.

Use the Heavy Duty Water Filtration System on a potable, 
safe-to-drink, home COLD water supply only. The filter
cartridge will not purify water or make unsafe water safe 
to drink. DO NOT use on HOT water (100

°

F max).

Protect the Heavy Duty Water Filtration System and piping
from freezing. Water freezing in the system will damage it.

Your Heavy Duty Water Filtration System will withstand up to
100 psi water pressure. If your house water supply pressure 
is higher than 100 psi during the day (it may reach higher
levels at night), install a pressure reducing valve before the
system is installed.

Do not install on 

HOT WATER

. The temperature of the

water supply to the Heavy Duty Water Filtration System
must be between the minimum of 40°F. and the maximum
of 100°F. See the 

Performance Data 

section.

Do not

install the Heavy Duty Water Filtration System using

copper solder fittings. The heat from the soldering process
will damage the unit.

WARNING:

Discard all unused parts and

packaging material after installation. Small parts
remaining after installation could be a choke hazard. 

Do not

install filter in an outside location or anywhere it

will be exposed to sunlight.

PROPER INSTALLATION

This Heavy Duty Water Filtration System must be properly installed and located in accordance with the Installation Instructions
before it is used.

GXWH30C is Tested and Certified by NSF International
against ANSI/NSF Standard 42 with Cartridge FXHTC
for the reduction of Chlorine: Taste and Odor.

251B6021P002   

(03-02 JR) 

49-50048-6   145287 Rev. D

www.GEAppliances.com

GENERAL ELECTRIC COMPANY, Appliance Park, Louisville, KY 40225

Summary of Contents for SmartWater GXWH30C

Page 1: ...ced directly upstream of your household filter Check with your local public works department for plumbing codes You must follow their guides as you install the Heavy Duty Water Filtration System Use the Heavy Duty Water Filtration System on a potable safe to drink home COLD water supply only The filter cartridge will not purify water or make unsafe water safe to drink DO NOT use on HOT water 100 F...

Page 2: ...ush the cartridge for 10 minutes wait one hour then flush again for 10 minutes before using the water 9 8 7 6 5 4 3 2 1 Installation Overview NOTE Be sure to allow a minimum space of 11 2 2 under the filter for removing the sump to change the cartridge Turn sump wrench tool clockwise to remove Sump Turn clockwise to remove canister Turn counterclockwise to tighten Red pressure release button Filte...

Page 3: ...be necessary to spread the pipe ends apart to install filter assembly Using two adjustable wrenches hold incoming adapter securely with one wrench and tighten nut with second wrench Repeat this procedure for outgoing adapter If necessary support the water pipe on either side of the filter unit 3 2 1 Final Check Install filter see Filter Cartridge Replacement Section Slowly turn on water supply Che...

Page 4: ...warranty for any indirect or consequential damage Products that are used for commercial or industrial applications Use of this product where water is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts Damage to the product caused by accident f...

Page 5: ...po Pièces GE Ensemble disponible HDKIT La performance de l appareil n a pas été testée et celui ci n a pas été homologué par NSF Attaches de mise à la masse homologuées UL et fil de mise à la masse en cuivre de calibre 6 trousse d installation disponible Pièces GE Ensemble disponible HDKIT La performance de l appareil n a pas été testée et celui ci n a pas été homologué par NSF Un Support HDBRKT R...

Page 6: ... 2 2 po sous le filtre pour l extraction du corps de filtre lors du changement de la cartouche Utiliser l outil spécial pour dévisser le corps de filtre rotation dans le sens horaire Corps de filtre Dévissage rotation dans le sens horaire Vissage rotation dans le sens antihoraire Bouton rouge de dépressurisation Cartouche de filtration Joint torique Corps de filtre Tête ÉTAPES DE L INSTALLATION Ro...

Page 7: ... la connexion montez un fil en cuivre de 18 po et de calibre 6 le long du filtre lequel sera fixé solidement au moyen d attaches en bronze homologuées par UL de dimensions variant entre 1 2 po 1 po à chaque extrémité comme indiqué N utilisez pas d attaches en zinc sur le cuivre Il est possible d acquérir le fil et les attaches séparément chez votre quincaillier ou en visitant notre site Web à www ...

Page 8: ...rantie ou toute autre garantie couvrant tout dommage indirect Produits utilisés pour des applications industrielles ou commerciales Utilisation de ce produit lorsque l eau est microbiologiquement impure ou de qualité inconnue sans qu une désinfection adéquate n ait eu lieu avant l entrée et sortie dans le circuit Les systèmes homologués pour une réduction des microbes peuvent être utilisés après d...

Page 9: ... arriba de su filtro de hogar INSTALACION CORRECTA Consulte con su departamento de obras públicas local para los códigos de plomería Usted debe seguir sus guías a medida que instale el sistema de filtración de agua extrafuerte Use el sistema de filtración de agua extrafuerte solamente en un abastecimiento de agua potable FRIA de hogar que sea buena para beber El cartucho del filtro no purificará e...

Page 10: ...o del filtro para sacar el receptáculo para cambiar el cartucho Haga girar la llave para el receptáculo en dirección del reloj para sacarlo Receptáculo Haga girar en dirección del reloj para sacar el receptáculo Haga girar contra el reloj para apretar Botón rojo para reducir la presión Cartucho del filtro Sello tipo anillo Receptáculo del filtro Cabeza INSTRUCCIONES DE INSTALACION PASO A PASO Válv...

Page 11: ...a Para restablecer la conexión instale un cable de cobre de 18 de calibre 6 a través del filtro fuertemente sujeto utilizando abrazaderas de tierra de bronce de 1 2 a 1 aprobada por UL en ambos extremos de la línea como se muestra en la ilustración Usted no debe usar abrazaderas de cinc en tubería de cobre El cable y las abrazaderas pueden ser compradas por separado en su ferretería local o están ...

Page 12: ...cuencia de otro evento Productos que son usados con fines comerciales o industriales Uso de este producto donde el agua está microbiológicamente insegura o de calidad desconocida sin la adecuada desinfección antes y después de ser procesada por el sistema Los sistemas certificados para reducir el nivel de quistes pueden ser usados en agua desinfectada que pueda contener quistes que se puedan filtr...