background image

Summary of Contents for SmartWater GXSF27B

Page 1: ...ly 12 Conuol displays 13 Electronic diagnostics 15 Features 13 14 Regenerating the system 16 Service 11 Water softener syslem 11 16 Care and Cleaning Cleaning out iron 16 Salt storage level and refill...

Page 2: ...my P READTHIS MANUAL Inside you xdll lind many helpfifl hints on how to use and inaintain your water systeln properly ust a little preventive care on yoln part can save you a great deal of time and mo...

Page 3: ...without adequate disinlection belore or after the system PROPER INSTALLATION This water softening system must be properly installed and located in accordance with the Installation Instructions before...

Page 4: ...ssachusetts Plumbing Code 248 CMR shall be adhered to Consult with your licensed plumber Use only lead tiee solder and flux tot all swea solder connections as required by state and tederal codes onnec...

Page 5: ...tric outlet and transformer are in an inside location to protect from wet weather Be sure tile oudet isunswit hed to prevent a cidenml shutoiL If installing in an outside loca0on you nmst take tile st...

Page 6: ...al 3 Valve Bypass Installation illustration Adapters forthisinstallationare notsupplied with thesoftener Toordertheseadapters callGEParts800 626 2000 Askfor Part WS6OX10006 Softwater 120 voltoutlet 24...

Page 7: ...before connecting pipes to the bypass calve Torch heat will damage plastic pmls When turning threaded pipe fittings onto plastic fittings use care not to cross thread Use pipe joint compound on all ex...

Page 8: ...pened in step A above Tuvalve hdet D Place bypass valve in the service position EXACTLY as follows KEEP SOFT WATER FAUCETS OPEN SLOWLY pull or slide the valve stem out toward the service position paus...

Page 9: ..._ tLa RDNESS do not show in the display press SEI_ECT until they do 1 Press the UP o or DOX VN _ button to set w ur water hardness number in the display DOWN W moves the display down u 1 UP _ moves ti...

Page 10: ...led with hard water and as hot water is used it will refill with soft water When all the hard water is replaced in the water heater hot only and mixed hot and cold water will be tully soft Ifyou want...

Page 11: ...me during the regeneration cycles the water heater will fill with the hard water Fill Salt dissolx ed in water is called brine Brine is needed to clean tl_e hard minerals flom resin beads To make the...

Page 12: ...tersoftening systemto workproperly This small unit makes tile surtion to move brine fl om tile salt storage area to tile resin tank during regeneration Ifit becomes plugged with sand dirt etc the wate...

Page 13: ...n immediate regeneration and xdmn oxer in about Ix_ohours you will haxe a new supply of sod water nee s aned you annot an el his regeneration Feature Program Memory If ele uical power to dm wmer soiie...

Page 14: ...l_e problem First make l_e 11 _dng vimal he ks VISUALCHECKS Is there ele tri al power m dm oudet dm water softening system mmsfbrmer is plugged imo _p _Is dmre sufficient sail in dm storage lank The t...

Page 15: ...orred switch operation CORRECT SWITCH DISPLAYS Ep VALVE CYCLE STATUS Valve in service fill brining backwash orfast rinse position Valve rotatingfrom one positionto another CWhile in this diagnostic sc...

Page 16: ...ning system valve and conuol However youmustkeep the tank supplied withsalt When to refill with salt Check tile salt level a tew weeks atier you install tile water soliening system and eve D week afte...

Page 17: ...ll with recommended salt Press fin 3 seconds the TOUCH or HOLDbutton to start an immediate regeneration and restore soft water supply Transformer unplugged at wall outlet or power cable to softener no...

Page 18: ...s a Does not use muth salt to regenerate very eflitient not using any salt demand unit Possible salt bridge See the Operating Instructions Tipsse tion Possible plugged nozzle and ventu6 See the Operat...

Page 19: ...ter installation _A ll go away after it runs tbr a while andis cloudy ErrorCode on control Wiring may have worked loose in control Unplug transti rmer Rem ve control cover release clips on side Check...

Page 20: ...Partslist 4 _ 16 56_ 55 56_ 10 18 I 1 If 28 29 36 _ _ 30 2O...

Page 21: ...Partslist 152 151 120 121 130 l 147 146 _ 21...

Page 22: ...0 COVER SAI T HOI E 1 1 1 0018 WS33X10001 SLAI VAPOR BARRIER 1 1 1 0019 WS33X10002 RIM 1 1 1 0020 WS31X10003 COVERBRINEWEI I 1 1 1 0021 WS02X10009 WING NUT 1 4 20 1 1 1 0022 WS32X10002 TANK BRINEWEII...

Page 23: ...BODYVALVE 1 1 1 0122 WS03X10020 SPRING 1 1 1 0123 WS22X10022 PLUG DtL_klN SALT 1 1 1 0130 WS35X10005 SL_LKIT 1 1 1 0132 WS22X10023 ADAPTERDtL_klN HOSE 1 1 1 0133 WS03X10021 O RING5 8 X13 16 1 1 1 0134...

Page 24: ...warranty you _ll be responsible fi r any labor or in home servi e osts What Is Not Covered Service trips to your home to teach you how to use the product Improper installation Failure of the product...

Page 25: ...his three year limited warranty y_ uwill be responsible fi r any labor or in home sevvice costs A replacement brine tank or cabine_ ifeither fails due to a detect in materials or workmanship During th...

Page 26: ...Notes 26...

Page 27: ...antes pour l insmllation 30 Sanitization 36 SpOcifications et dimensions 36 Instructions d utilisation eonseils Aflichages du panneau de commande 39 Diagnostics alecuxmiques 41 F_limination d un pont...

Page 28: ...e d achat LISEZ VOTRE MANUEL V_ usy rouverez de nombreux conseils pour l utilisation et 1 entretien de votre adoudssem d emL Ces quehlues mesures preventives w us pem_ettront d economiser du temps et...

Page 29: ...r le plan microbiolo_que ou sisa qualite n est pas rouv _esans qu elle n ait dt_ ddsinfbct_e avant ou apr_s avoir dt_ trait _e par l appareil UNEINSTALLATION ADEQUATE Avant d utiliser votre adoucisseu...

Page 30: ...MR Veuillez consulter votre plombier qualifi Utilisez seulement la soudure et le flux d_capant sans plomb p_ ur tousles branchements efiectu_s _l aide de s_ udures tendres comme presoit par les codes...

Page 31: ...ise est hers tension afin de pr4venir tom arr_t a ddemel Si l appareil est installd 5 l extdrieur prenez mutes les dispositions n4cessaires pour xous assurer que Fadoucisseur les conduites serxant _ _...

Page 32: ...vation a 3 voies Lesadaptateurs pourcetteinstallationnesontpasfournisavecradoucisseur Pour commander cesadaptateurs appelez leservice despi_ces deGEaunum6ro 800 626 2000 et demandez lapieceportantle n...

Page 33: ...raccords de myaux dans les raccords en plasfique faites attention de ne pas foirer le filetage U filisez un uomposa sin tousles filetages ex ernes des m _mx Faire un support pour la m vtuterie d mTiv_...

Page 34: ...position _service _ _rvice EXACTEMENTcomme suit GARDEZ _ _ 2 w_ _v Verslerob oct LIES ROBINETSD ALIMENTATIONEN FAUTRAITEE SUR LA POSITION OUVERTE d entrb_e Tirez LENTEMENT oufaites gfisserla t Nedu ro...

Page 35: ...oZ Haut ou DOWN _ Bas pour r4gler la hnet4 de l eau dm_s la ten tre d attichage Le bouton DOWN W Bas tait descendre l attichage sur 1 Le bouton UP Haut passe l attichage sur la valeur maximale NOTE Ch...

Page 36: ...aldt eau est rempli d eau hHe non traiff_e et au fin et _ t mesure que l eau est consonmV_e celle ci est remplacde par de l eau uaiff_e et l eau bouillante ainsi que le m qange eau bouillante eau fioi...

Page 37: ...r_g_n _ration avecde eau dure nontraitOe Remplissage I_e sel dissout dans l ean ea appeK solution saline Ceue solution est requise pour enlever les min4mux durs des grains de r4sine Pour tiJbriquer la...

Page 38: ...ucisseur d eau requiert tin gicleur et un venturi propres Au __nns de la r_g_n_ration ce petit ensemble assure la succion pour transporter la solution saline de la zone d entreposage h_sel au reservoi...

Page 39: ...e immd fiamment un processus de rdgdndration et une lifts l op afion terminde au b_ ut deux heures environ w us disposerez de suflisamment d eau traitOe Une lifts que la reg l ation a commence vous ne...

Page 40: ...ns laquelle Fadou isseur est bl_tn l _ ibn ionne l elle Y a ilsufiisamment de sel darts le r_ servoir I_e ff servoir doiI _ue au moins de 1 3 _ _ 1 2 plein BLe lapet de d_ rivation de laadou isseur di...

Page 41: ...6rifier le fimctionnement de l intermpteur AFFICHAGES CORRECTS DE L INTERRUPTEUR Ep STATUT DUCYCLE DUCLAPET Clapeten service remplissage lavageavec la solutionsaline positionde refoulement ou de rin a...

Page 42: ...es lesrdga tarations L eauser_a itafi_briquer las_ lut on sarneestdos daks leraser_ rdusel graceaur_ l inet etauxcommaltdes dus st me ad_ mcisseur d eau Cepondant vans devez veiller ace qne leselrempl...

Page 43: ...si le reservoir est vide remplissez le avec le sel recommande Appuyez pendant 3 secondes sur le bouton TOUCHor 14010 Appuyez ou Maintenez p ur declencher une regeneration immediam et pour re ablir l a...

Page 44: ...nt Ceci esl normal du systeme adoucisseur la duret6 de l ean d eau eauparait tre aglissante J_ te systeme adoucisseur Le syst6me adouclsseur d eau est un I ne Lml pas beaut ou I de se pour rdg4ndrer d...

Page 45: ...teur presentsdansI eaude tableet dansI_vier Bruits de I appareil L eau coulant de l appareilvers l orifice Ced est norlnal de vidange I1y a de Fair dans le syst_me apr_s I_es bulles dispm aitront apre...

Page 46: ...Listedespieces 4 _ 16 L_ __ 56_ 55 56_ 10 18 I i If 28 5 0 29 36 _ _ 30 46...

Page 47: ...Listedespi6 ces 152 151 120 121 141 138 1331 25 130 147 146 47...

Page 48: ...1 1 COUVERCI DUDISTRIBtTEtR I 1 I FONDD DISTRIBtTE R 1 1 1 R 2SINE 1I I CUBE I 1 I Rf2SERVOIR DERESINE l Rf2SERVOIR DER_2SINE I l COUVER IEDE FOND l l l COETER E I UPANND_U I EC _I _L4NI E l l l t AN...

Page 49: ...0122 WS03X10020 RESSORT 1 1 1 0123 WS22X10022 BOUCHON VIDAN EDI SEI 1 1 1 0130 WS35X10005 TROUSSEDEJOINTS 1 1 1 0132 X_ S22Xl 023 ADAPTEI RPOI RTI YAI DE 1 1 1 VIDANGE 0133 WS03X10021 JOINTTORIOUES 8...

Page 50: ...Notes 50...

Page 51: ...rle remplacement dureservo desolution saline oudureservo de resinesi l un ou l aune prdsente un ddfaut matdriel ou de thbri ation Au ours de erie garantie limitee de dix annees vous serez responsable...

Page 52: ...e ser_dce aux consommateurs de E sera toujours prdsent lorsque votre garantie sera expirde Au Canada appelez le 1 800 461 3636 Pieces et accessoires Aux I_tats Unis 800 626 2002 I es personnes qualif...

Page 53: ...s importantes 56 Consejos sobre las instrucciones de oTheraci6n Caracteristicas 35 3 3 C6mo limpiar la ensambladura de la boquilla y el Venturi 64 C6mo regenerar el sistema 68 Diagn6sticos electr6nico...

Page 54: ...ar_ mu has ideas fltiles de c6mo usar y mantener su sistema de agua apropiadamente Un po o de uidado preventive de su pane le puede ahonar mu ho tiempo y finero durante la vida de su sistema SINECESIT...

Page 55: ...o la desintecci6n adecuada antes o despuas del sistema INSTALACION APROPIADA Estesistemade descalcificaci6n de aguadebeser instaladocorrectamente y localizadodeacuerdo alas instrucciones de instalaci6...

Page 56: ...justarse al C6digo de Plomeria 248 CMR Consulte a su plomero certificado Use solamenm fimdenm y solda hna sin plomo pma todas las conexiones dulces soldadas segOn los c6digos estatales y tederales apl...

Page 57: ...rese de que el tomacorriente estd desconectado pare prevenir un corte el4cnico accidental o Si se dispone a llevar a cabo la instalacidn en el exterior usted debe dar los pesos necesarios para asegura...

Page 58: ...on de un bypassde 3 valvulas Losadaptadores paraestainstalaci6nnovienenincluidosconel descalcificador Para ordenar estosadaptadores Ilame a GE al 800 626 2000 Solicitelaparte WS6OX10006 58 Valvulade b...

Page 59: ...soldaduras antes de coneetar los tubos a la vfilvula de bypass El calor to antorcha daft arfi las partes pl_sticas _uan to se encuertu e giran lo aBlstes lie tul eiia roscados hacia isles plfisticos c...

Page 60: ...m haci6n del descalcificador comienee lenmmente E Despudsdeunos3minutos abram_grlfodeaguaCALIENTEpor lnfinum ohastaquetodoelaire hayasido extraido entonces ci6_Telo NOTA Si parece que el agalaestfitur...

Page 61: ...o de titctoria no se muestran en la pantalla optima SEI CT hasta que aparezcan 1 prima los botones UP _ o D WN _ parD ajustar la dureza del ag_la en la pantalla D YO I6 _ mueve la visualizaci6n hacia...

Page 62: ...agua dura a lnedida lue el aKua calierlte va a sierldo usada el calentador se llenarfi corl ag ua descalcilicada Cuar_do toda el agua dura sea reempl_ada en el calentador de agua el agala caliente _ e...

Page 63: ...Ilenara con agua dura tlenado E1agua disueha en agua es llacnada salmuera I_a salmuera es necesaria para liml iar los minerales duros de las dinlilmtas parttculas de resina Para rmar la salmuera el ag...

Page 64: ...alcificacion deaguafuncioneapropiadamente Esta pequefla uni ld eje uta la sucti6n pma mover la salmuera del _hea de almacenmniento de sal hada el mnque de resina duranm la regenerad6n Si esl i atascad...

Page 65: ...nza una regeneraci6n inmediata y uando termine en unas dos horas usted ten ha un m_evo suministro de agua descalcificada Una vez haya ini iado usted no Dlede can elar la regeneracidn Caracteristica Me...

Page 66: ...ones visuales INSPECCIONES VISUALES _4Hay energia el_cuica enmmdo hacia el omaconieme en el cual el nansf_ rmador de sislema de descalcificaci6n de agua esl_ conectado _Hay stfliciente sal en el tanqu...

Page 67: ...a peraci6n de cada interpaptor ELINTERRUPTOR CORRECTO MUESTRA p ESTADOOELCICLO DE LA VALVULA Posici6nde lvula en servicio Ilenado procesode salado lavadoregresivoo enjuaguer_pido La lvula est_ rotando...

Page 68: ...cificacion de agua Inspeccione el nivel de almacenamiento de la sal y el rellenado Se necesita sah nuera sal disueha en agua para cada regeneraci6n E1agua para hacer la sah nuera es medida cuando enu...

Page 69: ...puente de sal o siel mnque est 1vac_o llene otra vez el mnque con sal prima pot tres seglmdos el bot6n TOUCH HOLD toque sostenga para dar inicio a la regenerad6n y restaurar el suministro de agua bla...

Page 70: ...ble puente de sal Consulte la Secci6n de Consojos para las Instrucciones do OperaciOn Boquilla o Venturi posiblemente Consulte la Seccidn de Consojos para las Instruccionos do Oporacidn obstruidos El...

Page 71: ...sistema despu_s de Esto desaparecerfi despuds de hal er funcionado un tiempo la instalacidn El cableado podria haberse aflojado en el control l esconecte el tc msformador Remueva la mpa del conm l lit...

Page 72: ...Listadepartes 4 4 _ 16 _ 14 56_ 55 56_ 10 22 _ 24 _ _ 23 26 _ 28 5 0 72...

Page 73: ...Listadepartes 152 151 120 121 _ I38 137 130 1331 25 147 73...

Page 74: ...TAPA DEI DISTRIBUIDOR 1 1 1 FONDODEI DISTRIBUIDOR 1 1 1 RESINA 1 PIECI_TBICO 1 1 1 TANO U E DE RESINA 1 TANQUEDERESINA 1 1 TAPADEI FONDO 1 1 1 TAPADEI CONTROI 1 1 1 CONTROl 1 CONTROl 1 1 ABIJL_kDO 1...

Page 75: ...DE APOYO PANTAI i A TAPON DE FIIJJO l GPM JUNTA BOQL II I A VENTURI 1L_NTAIIA CONICA TAPON FI U O DE II ENADO 3 d M TU ERCA CONTERA ENSAMBIADUIL_ DE IA BOQUIIIA VENTURI RETENEDOIL_ SEI I O DE AR TORI...

Page 76: ...arantia la compra original limitada usted ser_ responsable por ualquier mano de obra o ostos de ser_d io en su asa Loque no esta cubierto Viajes de servicio a su casa para ensefiarle como usar el prod...

Page 77: ...Notas 77...

Page 78: ...Notas 70...

Page 79: ...ervidos al Consumidor GE estara fisponible despues de la fedm de expirad6n de la garanda PartesyAccesorios 800 626 2002 Aquellos indMduos que sepan c6mo u servMo asuspropios electrodomOsticos pueden s...

Page 80: ...al dis ount iE Consumer Se_4ce will still be there atier your warranty expires In Canada call 1 800 461 3636 PartsandAccessories n the U S 800 626 2002 Individuals qualified to se_x i etheir _1_applia...

Reviews: