Reverse Osmosis Cartridge Replacement

NOTE: 

When replacing the Reverse Osmosis cartridge, also install a new flow

control and screen.

It’s time to replace the Reverse Osmosis cartridge when the amber “RO”
light, on the faucet base, flashes continually while Reverse Osmosis
water is taken from the faucet.

Follow steps 1 through 6 in the Prefilter Cartridge Replacement.

Slide the new Reverse Osmosis cartridge into the top of the prefilter

cartridge. Then, place the assembled cartridges into the Reverse
Osmosis housing.

Remove and replace the flow control and screen. See figure on page 9.

Lightly lubricate the cap o-ring seal with clean silicone grease. Then,

push the cap into position and install the clamp sections and retainers.

Turn on the water supply and 

PURGE THE REVERSE OSMOSIS

CARTRIDGE. 

See the 

Purging the Reverse Osmosis system

section.

CAUTION:

The Reverse Osmosis cartridge contains a food grade

preservative that should be purged from the system before use. The
preservative will give product water an unpleasant taste and odor. After 
the tank has filled (takes about four hours), open the system faucet until the
bladder is empty. After about four of these drainings, the system is ready 
to make product water for your use

.

5

4

3

2

1

Flow Control and Screen for the Reverse Osmosis Cartridge

The flow control is vital for proper operation of the Reverse Osmosis
cartridge. The control keeps water flow through the cartridge at the
proper rate to obtain the best quality product water.

When servicing the Reverse Osmosis, it’s good practice to check the flow
control (and tubing to it) to make sure the small tube and surrounding
surfaces are clean and unrestricted. A small, cone-shaped screen is located
in front of the flow control to help keep it clean. If the flow control should
plug with foreign particles, the Reverse Osmosis cartridge cannot discharge
minerals and impurities to the drain. If this should happen, it will only take 
a short time for the cartridge to plug, making it useless.

CAUTION:

To replace the screen, place the cone end into the

Reverse Osmosis cap. Then, carefully push it in using 1/4

tubing as a

tool. Do not force in farther after you feel resistance. Visually check to
be sure it is properly positioned.

When installing the flow control, tighten the tubing nut by hand, then
another 1/4 to 1/2 turn with pliers. 

DO NOT OVERTIGHTEN AND DISTORT

OR CRUSH THE TUBING AND FLOW CONTROL.

Summary of Contents for Smart Water PNRV18ZWW01

Page 1: ...WH01 PNRV18ZWW01 GE Appliances GE Answer Center 800 626 2000 Owner s Manual 7178919 Part No 215C1002P005 1 Pub No 49 5803 Osmosis Filtration System Reverse Faucet Base Tested and certified to ANSI NSF...

Page 2: ...me you use your water system That s important because your new system will be part of your family for many years And we hope you will be part of ours for a long time to come We thank you for buying GE...

Page 3: ...in just a few minutes This Owner s Manual can tell you how You ll find many answers to common problems here If you review our chart of Troubleshooting Tips first you may not need to call for service a...

Page 4: ...s over the maximum 125 pounds per square inch install a pressure reducing valve in the water supply line to the Reverse Osmosis system Read the other limits pH water hardness etc in the Specification...

Page 5: ...it Do not attempt to treat water over 100 F Do not install on HOT WATER The temperature of the water supply to the Reverse Osmosis system must be between the minimum of 40 F to the maximum of 100 F S...

Page 6: ...pH limits pH 4 10 Percent rejection of TDS minimum new membrane 92 Chlorine removed maximum of 2 0 ppm by the Reverse Osmosis Prefilter regular replacement of the prefilter is required Chlorine will d...

Page 7: ...s directly to the drinking water faucet or to the storage tank The system includes an electronic faucet assembly with an integrated water testing feature When water is taken from the faucet a green in...

Page 8: ...artridge IMPORTANT See prefilter in the Care and Cleaning section Product Water Storage The storage area holds up to 1 9 gallons of product water The flexible bladder keeps water pressurized for fast...

Page 9: ...the faucet product water goes to the postfilter The postfilter is also the activated carbon type sediment filter Any remaining tastes odors or sediments are removed from product water Clean high qual...

Page 10: ...providing you with higher quality drinking water NOTE The green light may stop flashing when the supply of Reverse Osmosis water is nearly gone and flow from the Reverse Osmosis faucet decreases This...

Page 11: ...are tightened Open the tank shutoff valve Turn on the water supply to the Reverse Osmosis system In about four hours pressure will start to build in the Reverse Osmosis system At that time carefully c...

Page 12: ...the prefilter cartridge the Reverse Osmosis cartridge and postfilter cartridge need replacement at certain intervals Use the following information to keep the Reverse Osmosis system properly serviced...

Page 13: ...cet and allowing water to run until it stops Remove the clamp retainers and clamp sections Separate the cap from the Reverse Osmosis housing no need to disconnect tubing and set aside NOTE If the cap...

Page 14: ...tinuing from Prefilter Replacement Procedure feedwater off pressure relieved Disconnect tubing at both ends See figure 1 page 9 Pull the filter from the holder and remove fittings from both ends Remov...

Page 15: ...led takes about four hours open the system faucet until the bladder is empty After about four of these drainings the system is ready to make product water for your use 5 4 3 2 1 Flow Control and Scree...

Page 16: ...is system by doing the following Be sure the water supply to the Reverse Osmosis system is turned off and the Reverse Osmosis faucet is open Remove the clamp retainers and clamp sections Lift the cap...

Page 17: ...bleach odor is gone Turn off the water supply to the Reverse Osmosis system Close the Reverse Osmosis faucet AFTER water flow stops Reconnect the postfilter replace a used filter to the Reverse Osmos...

Page 18: ...brane is no Osmosis membrane Disregard initial or longer removing the cartridge flow occasional short periods required amount of control and screen of this flashing light total dissolved solids Water...

Page 19: ...Replace the postfilter changed If taste and odor persist replace the prefilter Reverse Osmosis Reverse Osmosis membrane cartridge membrane cartridge needs to be changed flow control screen and batter...

Page 20: ...uum relief from the Reverse Osmosis the storage area for valve and allow the tank to faucet product water fill with air Water leaking from Drain side of faucet Inspect and eliminate faucet airgap hole...

Page 21: ...onsumer Product Ownership Registration Important Mail Today GE Appliances Place in an envelope and mail to General Electric Company Warranty Registration Department P O Box 34070 Louisville KY 40232 4...

Page 22: ...ontact you in the unlikely event of a safety modification After mailing the registration below store this document in a safe place It contains informa tion you will need should you require service Our...

Page 23: ...t your local or state consumer affairs office or your state s Attorney General For The Period Of GE Will Replace One Year Any part of the Reverse Osmosis Filtration System which From the date of the f...

Page 24: ...dividuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover cards are accepted Instructions contained in this manual cov...

Reviews: