Hood Exhaust Duct

Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.

EXHAUST CONNECTION:

 

The hood exhaust has been designed to mate with a standard 3-1/4” x 10”  

rectangular duct.
If a round duct is required, a rectangular-to-round transition adaptor must be used. 

Do not use less than a 6” diameter duct.

REAR EXHAUST:

 

If a rear or horizontal exhaust is to be used, care should be taken to align exhaust 

with the space between studs, or wall should be prepared at the time it is constructed 

by leaving enough space between the wall studs to accommodate exhaust.

Duct 

Equivalent

A.

  Rectangular-To-Round 

5 Ft. 

  Transition Adaptor

B.

  Wall Cap 

40 Ft.

C.

  90° Elbow 

10 Ft.

D.

  45° Elbow 

5 Ft.

E.

  90° Elbow 

25 Ft.

F.

  45° Elbow 

5 Ft.

G.

  Roof Cap 

24 Ft.

Grille

Filter Kit Accessory

Filter Kit

JX81A–Recirculating 

Charcoal Filter Kit
To be used when  

the Advantium oven  

cannot be vented  

to the outside.

MAXIMUM DUCT LENGTH:

 

For satisfactory air movement, the total duct length of 3-1/4” x 10”  

rectangular or 6” diameter round duct should not exceed  

140 equivalent feet.

ELBOWS, TRANSITIONS, WALL AND ROOF CAPS

, etc., present additional  

resistance to airflow and are equivalent to a section of straight duct 

which is longer than their actual physical size. When calculating the 

total duct length, add the equivalent length of all transitions and adaptors 

plus the length of all straight duct sections. The chart below shows the 

approximate feet of equivalent length of some typical ducts.