Troubleshooting
S768DAV – S7768DAV User Manual
5
T
ROUBLESHOOTING
Table 15 contains troubleshooting information for the S768DAV units.
Table 15. Troubleshooting
Problem Probable
Cause
Solution
Red LASER LED
Laser is malfunctioning
Replace module
Fiber not connected
Connect fiber to receiver and transmitter
Red LEVEL/LOSS LED
Transmitter/Receiver not powered up
Connect and apply power to module
Video input not connected to module
Connect video input to module
Video source not powered up
Apply power to video source
VIDEO IN/OUT LED is OFF
Video source not transmitting
Check video source and cabling
Audio input not connected to module
Connect audio input to module
Audio source not powered up
Apply power to audio source
AUDIO IN/OUT LED is OFF
Audio source not transmitting
Check audio source and cabling
Tri-state condition
No action required
Data input not connected to module
Connect data input to module
Data source not powered up
Apply power to data source
DATA IN LED is OFF
Data source not transmitting
Check data source and cabling
Red ENABLED 1 and/or 2 LED Test or invalid mode selected
Set DATA SELECT switch to valid format
ENABLED 1 and/or 2 LED
flashing red/green
Both Transmitter and Receiver set to
Auto Configure mode
Set Transmitter or Receiver DATA
SELECT switch to valid format
ENABLED 1 and/or 2 LED
flashing red/off
Invalid or Test mode configured
remotely
Set DATA SELECT switch to valid format
if not in Test mode
26
11-0768DAV-B/ December 2003