![GE RHM 15 Specifications Download Page 5](http://html.mh-extra.com/html/ge/rhm-15/rhm-15_specifications_128436005.webp)
Pressure Rating RHM 15
The maximum pressure (pmax) of a sensor is determined by its weakest part. The weakest part can be the measuring
loops (pmax indicated below) or the construction type (pmax indicated in the Basic Order Code section, last page) or the
selected flanges / fittings (for pmax please see respective standard).
pmax of P1 measuring loops, standard
M1 standard material - 1.4571 (316Ti)
OD x WT 15 x 1 mm (0.59 x 0.039 in)
bar
°C
psi
°F
165
50
2393
122
150
120
2176
248
127
210
1842
410
107
350
1552
662
pmax of P2 measuring loops
M1 standard material - 1.4571 (316Ti)
OD x WT 15 x 2 mm (0.59 x 0.079 in)
bar
°C
psi
°F
352
50
5105
122
300
120
4351
248
250
210
3626
410
210
350
3046
662
pmax of P3 measuring loops
M1 standard material - 1.4571 (316Ti)
OD x WT 15 x 3 mm (0.59 x 0.118 in)
bar
°C
psi
°F
540
50
7832
122
450
120
6527
248
350
210
5076
410
300
350
4351
662
pmax of P1 measuring loops
M3 optional material - 2.4602 (Alloy C22)
OD x WT 15 x 1 mm (0.59 x 0.039 in)
bar
°C
psi
°F
228
50
3307
122
201
120
2915
248
172
210
2495
410
143
350
2074
662
pmax of P2 measuring loops
M3 optional material - 2.4602 (Alloy C22)
OD x WT 15 x 2.2 mm (0.59 x 0.087 in)
bar
°C
psi
°F
540
50
7832
122
477
120
6918
248
407
210
5903
410
339
350
4917
662
5