GPS Grandmaster Clock
32
RT430-TM-EN-5
2.7.1
AC Power Connection
Phase conductor should be applied to terminal 1, neutral conductor to terminal 2 in each of the supply
terminals identified as Power 1 and Power 2 as shown in
Figure 8: AC power connection
For compliance with IEC 61010, install a suitable external switch or circuit breaker in each current-carrying
conductor of RT430 power supply; this devccccice should interrupt both the hot (+/L) and neutral (-/N) power
leads. An external 10 A, category C, bipolar circuit-breaker is recommended. The circuit breaker should have
an interruption capacity of at least 25 kA and comply with IEC 60947-2. The switch or circuit-breaker must be
suitably located and easily reachable, also it shall not interrupt the protective earth conductor.