Parts Included
Materials Needed (Field Supplied Parts)
Installation Instructions
for your new
Before you begin - Read these instructions completely and carefully.
IMPORTANT – OBSERVE ALL GOVERNING CODES AND ORDINANCES.
Note to Installer – Be sure to leave these instructions with the Consumer.
Note to Consumer – Keep these instructions with your Owner’s Manual for future reference
.
RAVRG3
Access Panel with
return air grille
95303007 31-30823 12-16 GEA
GE is a trademark of the General Electric Company. Manufactured under trademark license.
Installation
Overview
Frame and sheetrock and access hole to 27” wide and 55 3/4 tall.
The bottom of the opening should be at the same level as the
floor or subbase that the VAC unit is placed on. The chassis must
fit thru this opening. The chassis is 23 1/2” wide and 32 1/4” or
47” tall (consult chassis specifications for actual dimensions).
Return Air Grille/
Access Panel
•
25” x 20” Filter
•
5/32” Allen wrench for latch mechanism operation
•
Return Air Grille/Access Panel with Latch Mechinism
(58” Tall x 29” Wide)
•
Mounting Side Bracket
•
Latch Bracket
•
Mounting Screws
Latch
Bracket
Mounting
Screws
Mounting
Bracket
Return Air Grille/
Access Panel
25” x 20” Nom. Filter
(field supplied)
Filter mounts on the
inside of Access Panel
Door
Filter
Left
Mounting
Side
Bracket
Latch
Mechanism