background image

31-5000558   Rev. 0   10-20   GEA

 

Tools Needed

• 5/16” nut driver
• Pliers
• Slotted screwdriver

Important Notes

• This unit must be properly grounded.

•  Read this instruction before installing the sub-base to the 

molded or metal case. 

The sub-base should be assembled to the case before 
securing the case in the wall.

CAUTION

Electrical power must be disconnected 

before installing the sub-base.

Electrical Requirements :

1.  Electrical wiring may enter the sub-base through any of 

the knockout holes provided in the sub-base bottom or 
rear. Use appropriate protection around the opening to 
ensure the wiring will not become cut or chafed.

2.  Refer to the unit nameplate for branch circuit 

requirements.

3.  All wiring should be done in accordance with the local 

electrical codes and regulations.

4. Not approved for aluminum wire application.

5.  If electrical wiring is placed in or against the sub-base 

enclosure, the sub-base must be grounded. Use the 
installed ground screw to connect the ground wire eyelet 
from the kit to the rear of the sub-base. 

See step 4.

Parts included in bag with Sub-
Base Switch Kit

Installation Instructions  
for your new

RAK204
Sub-Base Switch Kit

Before you begin - Read these instructions completely 
and carefully. IMPORTANT – OBSERVE ALL 
GOVERNING CODES AND ORDINANCES. Note to 
Installer – Be sure to leave these instructions with the 
Consumer. Note to Consumer – Keep these instructions 
with your Owner’s Manual for future reference.

RAK204SW kit compatible with the following Sub base models

Kit Number 

Description

RAK204E15C

265 V

15 A

RAK204E20C

265 V

20 A

RAK204E30C

265 V

30 A

RAK204D15C

230/208 V

15 A

RAK204D20C

230/208 V

20 A

RAK204D30C

230/208 V

30 A

5/16” Nut

Sub-Base 

Switch

Wire Nuts (4)

Summary of Contents for RAK204

Page 1: ...al codes and regulations 4 Not approved for aluminum wire application 5 If electrical wiring is placed in or against the sub base enclosure the sub base must be grounded Use the installed ground screw...

Page 2: ...ws STEP 2 Place the Sub base switch in the OFF position Hold the sub base switch assembly and thread the wires into the left side opening and across toward the right side of the sub base The wires lab...

Page 3: ...e Sub Base using the retained screws STEP 4 To attach the ground wire from the Sub Base Switch place the ring terminal onto the existing ground screw and secure with the provided 5 16 lock nut Existin...

Page 4: ...to connect the Sub base switch to the electrical sub base wiring See diagram above STEP 6 Reattach the middle and right side face plates using the screws saved from step 1 STEP 7 Verify wiring and res...

Page 5: ...Tout le c blage lectrique doit tre r alis conform ment aux codes et r glements locaux 4 Le c blage en aluminium n est pas approuv 5 Si le c blage lectrique est positionn dans ou contre le bo tier de...

Page 6: ...rrupteur de socle la position OFF Tenez l interrupteur de socle et passez les fils dans l ouverture du c t gauche et travers le c t droit du socle Les fils identifi s To Power Source la source d alime...

Page 7: ...serv es TAPE 4 Pour fixer le fil de mise la terre de l interrupteur de socle placez la cosse anneau sur la vis de mise la terre existante et fixez le tout avec l crou de blocage de 5 16 po fourni Fil...

Page 8: ...nterrupteur de socle au c blage du socle lectrique Consultez le sch ma ci dessus TAPE 6 Fixez de nouveau les plaques frontales centrale et droite l aide des vis conserv es l tape 1 TAPE 7 V rifiez le...