Introduction

This manual provides operating instructions for the PV 411A Pneumatic/Hydraulic hand-
pump compatible with the requirements of line operation. The PV 411A supersedes the 
PV 411.

Safety

The manufacturer has designed this equipment to be safe when operated using the 
procedures detailed in this manual. The user must not use this equipment for any other 
purpose than that stated. Only use hydraulic fluids stated in the specification.
This manual contains safety and operating instructions that must be followed to make sure of 
safe operation and to keep the equipment in a safe condition. The safety instructions are 
either warnings or cautions issued to protect the user and the equipment from injury or 
damage.
Users are to check that there is no visible gap or play between the plastic halves of the 
PV 411A prior to use. If a visible gap or play is evident, do not use, contact your local Service 
Center. See Section 6.2 on page 13 for more details.
Use suitably qualified technicians

*

 and good engineering practice for all procedures in this 

manual.

Pressure

Do not apply pressure greater than the maximum safe working pressure stated in the 
specification.

Toxic Materials

There are no known toxic materials used in construction of this equipment.

Maintenance

The equipment must be maintained using the procedures in this publication. Further 
manufacturer’s procedures should be done by an authorized service agents or the 
manufacturer’s service departments.

*

A qualified technician must have the necessary technical knowledge, documentation, special test 
equipment and tools to carry out the required work on this equipment.

Summary of Contents for PV411A

Page 1: ...Data Classification Public Druck PV 411A Pneumatic Hydraulic Hand pump Instruction Manual English 1 14 Deutsch 15 28 Espa ol 29 42 Fran ais 43 56 Italiano 57 70 Lietuvi 71 82 Norsk 83 94 Portugu s 95...

Page 2: ......

Page 3: ...2000 Baker Hughes a GE company All rights reserved PV 411A Instruction Manual English i 8 3 1 7 6 2 3 5 4 A1...

Page 4: ...ii PV 411A Instruction Manual English 2000 Baker Hughes a GE company All rights reserved 1 2 4 3 2 3 1 A2 A3...

Page 5: ...ct the user and the equipment from injury or damage Users are to check that there is no visible gap or play between the plastic halves of the PV 411A prior to use If a visible gap or play is evident d...

Page 6: ...ilisateur doit consulter le manuel d utilisation Do not dispose of this product as household waste Use an approved organization that collects and or recycles waste electrical and electronic equipment...

Page 7: ...tion handles 5 provides the pumping stroke for pressure generation A volume adjuster 3 allows small adjustments of the system pressure 1 2 Hydraulic Pump Figure A1 The selector valve 7 vents the syste...

Page 8: ...2 and 6 In vacuum mode the air fluid flow is reversed as air fluid is drawn in through the top and rear outlet ports 2 and 6 and expelled through the inlet port 1 WARNING Before applying pressure mak...

Page 9: ...sed to achieve pressure seal If excess tape is used particles can become loose during the connector mating process and enter the pump potentially leading to loss of pump performance or pressure leaks...

Page 10: ...1 1 Low Pressure 1 With the selector valve set to vent open turn the volume adjuster fully counterclockwise out 2 Turn the selector valve to the fully clockwise in position to select pressure 3 Turn t...

Page 11: ...he scissor action handles 5 to generate the approximate pressure allow time for thermal stabilization 3 If necessary use the volume adjuster 3 to adjust the required pressure 4 After attaining the req...

Page 12: ...he inlet port on the top of the pump and supplies fluid to the pump system for pressure generation In vacuum mode used in priming the fluid flow is reversed fluid is drawn from the two outlet ports an...

Page 13: ...acuum sensitive equipment 3 Turn selector valve fully out counterclockwise vacuum position 4 Turn the volume adjuster valve fully counterclockwise out position 5 Pump until bubbles stop appearing in t...

Page 14: ...he volume adjuster 3 fully out counterclockwise and turn the selector valve 7 to depressurize the pump Disconnect from the pipes and equipment 4 6 Setting Pressure Relief Valve Figure A3 The pressure...

Page 15: ...ightened 2 Allow sufficient time after pressure generation for the temperature to stabilize The larger the system volume the longer the time for thermal stability 3 Check the adaptors flexible pipe an...

Page 16: ...INFORMATION Hydraulic fluids must be compatible with stainless steel anodized aluminum nitrile rubber PTFE polypropylene Delrin acrylic and nylon Item Specification Pneumatic Pressure Range 0 to 60 b...

Page 17: ...ct has been in contact with any hazardous or toxic substance The relevant COSHH or in the USA MSDS references and precautions to be taken when handling 6 2 Approved Service Agents For the list of serv...

Page 18: ...14 PV 411A Instruction Manual English 2000 Baker Hughes a GE company All rights reserved...

Reviews: