Page 45
XI. SPECIAL EDITION ON MAINTENANCE OF ENVIRONMENTAL PROTECTION
REFRIGERATOR
11.3.2
Reactions for HFC-134a
i.
Upon welding the tube, blow with
nitrogen to avoid the capillary tube
clogging by the oxidized membrane.
ii.
Aiming at the improvement of vacuum
degree for the vacuum pump of
pressure gauge, install additional
valves for the equipment using bolt to
keep non-condense air from getting
in.
iii. Shorten the service time as indicated
in the figure. Operate by the tubing
type as shown on the figure below:
1
st
time vacuum extracting (5 min.)
Fill the freon in (50 gr)
2
nd
time vacuum extracting (20 min.)
Fill the freon in (reqd amount)
Compound
Pressure Gauge
Additional valve
Freon filling tank
H pressure
tube
L pressure
tube
Freon tank
Vacuum pump
L
H
iv.
The tool cannot be used together with
the existing CFC-12. So the tool
must be re-ordered to avoid incorrect
use. Each connecting part will be
changed from 1/4 inch to 3/8 inch.
Summary of Contents for PTG440SAMR
Page 53: ...Page53 XII PART LIST AND EXPLODED VIEW PTV15SAMR PTU427SAMR PTQ440SAMR PTG440SAMR ...
Page 54: ...Page54 XII PART LIST AND EXPLODED VIEW PTV15SAMR PTU427SAMR PTQ440SAMR PTG440SAMR ...
Page 61: ...Page61 XII PART LIST AND EXPLODED VIEW PTV16SAMR PTU463SAMR PTQ470SAMR PTG470SAMR ...
Page 62: ...Page62 XII PART LIST AND EXPLODED VIEW PTV16SAMR PTU463SAMR PTQ470SAMR PTG470SAMR ...
Page 70: ...Page70 XII PART LIST AND EXPLODED VIEW PTV19SAMR PTU527SAMR PTQ530SAMR PTG530SAMR ...
Page 71: ...Page71 XII PART LIST AND EXPLODED VIEW PTV19SAMR PTU527SAMR PTQ530SAMR PTG530SAMR ...
Page 78: ...Page78 XII PART LIST AND EXPLODED VIEW PTV20SAMR PTU565SAMR PTQ570SAMR PTG570SANR ...
Page 79: ...Page79 XII PART LIST AND EXPLODED VIEW PTV20SAMR PTU565SAMR PTQ570SAMR PTG570SANR ...