background image

Listed by 

Underwriters 

Laboratories

For answers to your Monogram,

® 

GE Profile

 or  

GE

®

 appliance questions, visit our website at 

ge.com or call GE Answer Center

®

 service, 

800.626.2000.

Dimension and installation information are shown in inches.

Specification Revised 4/09

220245

PT925SN 

GE Profile

 30" Built-In Single/Double Convection Wall Oven

 

KW Rating

240V

3.9

208V

2.9

Breaker Size

240V

20 Amps

208V

20 Amps

Most 30” Wall Cabinets can be used with this unit.
Note:

 

These ovens are not approved for 

stackable installations.

 Cabinets installed 

adjacent to wall ovens must have an adhesion 
spec of at least a 194°F temperature rating.
Door handle protrudes 3"

 

from door face. Cabinets 

and drawers on adjacent 45° and 90° walls should 
be placed to avoid interference with the handle.

Electric wall ovens are not approved for 

installation with a plug and receptacle. They 

must be hard wired in accordance with  

installation instructions

Installation Information:

 Before installing, consult 

installation instructions packed with product for 
 current dimensional data.
Side-by-side installations require at least 2" 
between cutouts.

CUTOUT

HEIGHT

27 1/4" MIN.

27 5/16" MAX.

CUTOUT

WIDTH

28 1/2" MIN.

28 5/8" MAX.

5"

22" TO

BOTTOM OF 

JUNCTION BOX

JUNCTION B

LOCATION

RECOMMENDED

CUTOUT

LOCATION

32 1/2"

FROM THE 

FLOOR

CABINET

WIDTH

30"

ALLOW 11/16" FOR

OVERLAP OF THE 

OVEN OVER SIDE

EDGES OF CUTOUT

THE OPENING 

BETWEEN INSIDE

 WALLS MUST

BE AT LEAST 

28 1/2"WIDE

ALLOW 1" FOR 

OVERLAP

ON OVEN TOP 

AND BOTTOM 

OF CUTOUT

21"

ALLOW A MINIMUM

F 21" FOR CLEARANCE 

ADJACENT CORNERS, 

RAWERS, WALLS ETC. 

N THE DOOR IS OPENED.

Allow 11/16

 

(1.75 cm)  for 

overlap of oven 

over side edges 

of cutout

Cutout

Width

28 1/2

” 

(72.4 cm)

Min.

28 5/8

” 

(72.7 cm)

Max.

15

(38.1 cm) 

Cabinet

Width

30

(76.2 cm) 

Allow a minimum 

of 15” (38.1 cm) for 

clearance to adjacent 

corners, drawers, 

walls, etc. when 

door is open

Allow 1” (2.5 cm) 

minimum for 

overlap of oven 

top and 1 1/4” 

(3.2 cm) overlap 

of oven bottom 

of cutout

Recommended 

cutout 

location from 

floor 26 1/2” 

(67.3 cm) max

Opening 

Between 

Inside Walls 

Must Be 

At Least 

28 1/2” 

(72.4 cm) 

Wide

Junction Box 

Location

(junction box 

may be 

located in 

adjacent 

cabinet)

9 1/2

” 

(12.7 cm)

Max.

Cutout

Height

27 1/4

 

(69.2 cm) Min. 

27 5/16

 

(69.4 cm) Max.

22

 (55.9 cm) 

Min. to

Bottom of 

Junction Box

CL

2 x 4 or

equivalent

runners

Suitable

bracing

to support

runners

21-5/8"

over centerline

of cabinet

(must support 275 lbs.)

Cutout width
28-1/2'' MIN.
28-5/8'' MAX.

29-3/4

C

30

Recommended 

cutout location 

32-1/2" 

from floor

21

Junction 

box

location

Allow minimum of 21'' for clearance

to adjacent corners, drawers, walls, or etc.
A=Allow 1" overlap of oven over top and bottom edges of cutout.

B=Allow 11/16"–3/4" for overlap of oven over side edges of cutout.

C=28-1/4" without trim and 28-3/4" with trim.

Conduit

(72" 

long)

5

27-1/4'' MIN.
27-5/16'' MAX.
Cutout height

A

B

23-1/2'' MIN.

Cutout depth

22'' MIN.

Dimensions and Installation Information (in inches)

Reviews: