![GE Profile Series Installation And Startup Download Page 5](http://html1.mh-extra.com/html/ge/profile-series/profile-series_installation-and-startup_4103475005.webp)
NX-590E Internet Interface
5
1. GENERAL
DESCRIPTION
The NX-590E is a dual microprocessor-controlled Internet/Intranet interface used to connect the
to the OH Network Receiver. This interface allows any or all events from the NetworX control
series (NX) to be reported over the Network. For warranty information, please refer to the
current GE Interlogix Product catalog.
2. ENCLOSURE
INFORMATION
Inside the can, several 2-holed insertion points have been
constructed. This allows for either vertical or horizontal
placement of the modules. Notice that the insertion
points have two sizes of holes -- a larger hole and a
smaller hole.
Diagram 1: The black plastic PCB guides are grooved on
one edge where the PC Board will be seated. The end with
the half-moon protrusion fits into the larger hole. The
smaller hole is for the screw.
Diagram 2: Place the first black plastic PCB guide in the
top insertion point, grooved edge downward. The half-moon
protrusion will be in the large hole. It does not require force.
Insert one of the provided screws into the smaller hole (from
inside the can) to secure it in place. A screwdriver should
reach through the notch that runs the length of the guide to
tighten the screw. The second PCB guide should be
positioned opposite of the first (grooved edge up) and
placed in the lower insertion point, using the same
procedures described above. Once mounted, screw it in
securely.
Diagram 3: The PC board should slide freely in the
grooves of both guides.
3. MODULE
ADDRESS
The Internet module has a fixed address of 79. When programming the interface module, enter
the Program Mode and select the device address as 79. (See "PROGRAMMING THE