Performance Data Sheet
SmartWater Filtration S
y
stem-GE
®
MWF Cartridge
This s
y
stem has been tested and certified in filter model GE MWF according to NSF/ANSI Standards 42 and 53 for reduction of the substances listed below. The
concentration of the indicated substances in water entering the s
y
stem was reduced to a concentration less than or equal to the permissible limit for water
leaving the s
y
stem, as specified in NSF/ANSI Standards 42 and 53.* (Safet
y
factors built in for unmetered usage)
Standard No. 42: Aesthetic effects
Substance
Reduction
Average Influent
NSF Specified Challenge
Concentration
Average %
Reduction
Average Product
Water Concentration
Max Permissible Product
Water Concentration
NSF Reduction
Requirements
NSF Test
Report
Chlorine Taste
& Odor
2.0 mg/L
2.0mg/L ± 10%
97.5%
0.05 mg/L
N/A
≥50%
J-00077703
Nominal Particulate
Class I, ≥0.5 to <1.0 μm
7,833,333 pts/mL At least 10,000 particles/mL 99.7%
18,617 pts/mL
N/A
≥85%
J-00077704
Standard No. 53: Health effects
Substance
Reduction
Average Influent
NSF Specified Challenge
Concentration
Average %
Reduction
Average Product
Water Concentration
Max Permissible Product
Water Concentration
NSF Reduction
Requirements
NSF Test
Report
Cyst*
147,5000 cysts/L Minimum 50,000 cysts/L
99.99%
1 cyst/L
N/A
≥99.95%
J-00077721
Asbestos
47 MF/L
10
7
to 10
8
fibers/L; fibers
greater than 10 μm in length
>99%
<1 MF/L
N/A
≥99%
J-00077707
Atrazine
0.009 mg/L
0.009 mg/L ± 10%
94.5%
0.0005 mg/L
0.003 mg/L
N/A
J-00077708
Benzene
0.016 mg/L
0.015 mg/L ± 10%
96.7%
0.0005 mg/L
0.005 mg/L
N/A
J-00077717
Carbofuran
0.08 mg/L
0.08 mg/L ± 10%
98.7%
0.001 mg/L
0.04 mg/L
N/A
J-00077718
Endrin
0.006 mg/L
0.006 mg/L ± 10%
95.6%
0.0003 mg/L
0.002 mg/L
N/A
J-00082185
Lead @ pH 6.5
0.152 mg/L
0.15 mg/L ± 10%
99.3%
0.001 mg/L
0.010 mg/L
N/A
J-00077722
Lead @ pH 8.5
0.148 mg/L
0.15 mg/L ± 10%
99.3%
0.001 mg/L
0.010 mg/L
N/A
J-00077723
Lindane
0.002 mg/L
0.002 mg/L ± 10%
99%
0.00002 mg/L
0.0002 mg/L
N/A
J-00077726
Mercury @ pH 6.5
0.0058 mg/L
0.006 mg/L ± 10%
93.2%
0.0004 mg/L
0.002 mg/L
N/A
J-00077727
Mercury @ pH 8.5
0.0061 mg/L
0.006 mg/L ± 10%
93.2%
0.0004 mg/L
0.002 mg/L
N/A
J-00077728
P-Dichlorobenzene
0.222 mg/L
0.225 mg/L ± 10%
99.7%
0.005 mg/L
0.075 mg/L
N/A
J-00077729
Tetrachloroethylene
0.015 mg/L
0.015 mg/L ± 10%
96.6%
0.0005 mg/L
0.005 mg/L
N/A
J-00082184
Toxaphene
0.015 mg/L
0.015 mg/L ± 10%
93.2%
0.001 mg/L
0.003 mg/L
N/A
J-00077730
2, 4-D
0.218 mg/L
0.210 mg/L ± 10%
99.5%
0.0009 mg/L
0.07 mg/L
N/A
J-00077705
*Based on the use of Cryptosporidium parvum oocysts
Capacity 300 gallons (1,135 liters). Contaminant reduction determined by NSF testing.
It is essential that the manufacturer's recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised.
See Installation Manual for Warranty information.
Application Guidelines/Water Supply Parameters
Service Flow
0.5 gpm (1.9 lpm)
Water Supply
Potable Water
Water Pressure
40–120 psi (2.8–8.2 bar)
Water Temperature
33ºF–100ºF (0.6ºC–38ºC)
Operating Specifications
• Pressure requirement: 40–120 psi (2.8–8.2 bar), non-shock
• Temperature: 33–100°F (0.6–38°C)
• Flow rate: 0.5 gpm (1.9 lpm)
General Installation/Operation/Maintenance Requirements
•
trapped air.
•
•
expected to drop below 33°F (1°C). Do not install s
y
stems in areas where
ambient temperatures ma
y
go above 100ºF or below 40°F. Do not install
on a hot water suppl
y
.
Special Notices
• Installation instructions are included with the product when shipped.
• This drinking water s
y
stem must be maintained according to manufacturer’s
instructions, including replacement of filter cartridges.
• Do not use with water that is microbiologicall
y
unsafe or of unknown qualit
y
without adequate disinfection before or after the s
y
stem. S
y
stems certified for
c
y
st reduction ma
y
be used on disinfected water that ma
y
contain filterable c
y
sts.
Standard No. 42: Aesthetic Effects
• Chemical
– Chlorine Taste and Odor
Tested and Certified b
y
NSF International against ANSI/NSF Standards 42 and 53 in model GE MWF for the reduction of:
• Mechanical Filtration
– Particulate Reduction, Class I
Standard No. 53: Health Effects
• Chemical Reduction
– Atrazine Reduction
–
Endrin
Reduction
– Benzene and Carbofuran Reduction
– 1,4 Dichlorobenzene and
2,4-D Reduction
– Lead and Lindane Reduction
–
Mercur
y
and Toxaphene Reduction
• Mechanical Filtration
–
C
y
st and Asbestos Reduction
• The contaminants or other substances removed or reduced b
y
this water
treatment s
y
stem are not necessaril
y
in
y
our water.
• Check for compliance with the applicable state and local laws and regulations.
• Note that while the testing was performed under standard laborator
y
conditions,
actual performance ma
y
var
y
. S
y
stems must be installed and operated in
accordance with manufacturer’s recommended procedures and guidelines.
• Installation and use MUST compl
y
with all state and local plumbing codes. Do not
install if water pressure exceeds 120 psi. If
y
our water pressure exceeds 80 psi
(552 kPa),
y
ou should install a pressure-limiting valve. Contact a plumbing
professional if
y
ou are uncertain how to check
y
our water pressure.
• Do not install where water hammer conditions ma
y
occur. If water hammer
conditions exist
y
ou must install a water hammer arrester. Contact a plumbing
professional if
y
ou are uncertain how to check for this condition.
•
controlling pressure due to thermal expansion must be installed.
GE
Appliances
Appliance Park
Louisville, KY 40225
geapplianceparts.com
© 2010 GE Compan
y
PC61278B
REPLACEMENT
ELEMENT
Summary of Contents for Profile PSCF5RGXBB
Page 45: ...45 Notes ...
Page 91: ...91 Notes ...