– 38 –
Troubleshooting Flowcharts
G as Dryer
Ignitor Glowing?
G as Supply O K to
dryer?
Y
Fix Supply
problem
Ignitor betw een 50 &
400 ohms at room
tem perature?
R eplace Ignitor
N
Manually push m otor centrifugal
sw itch & check for continuity
betw een M1&M2?
N
R eplace gas
valve assembly
Y
N
Y
N
Flam e Detector
contacts open after
ignitor on 15-90
seconds?
N
R eplace Detector
C heck Inlet safety & outlet
backup t’stats. C losed circuits?
R eplace open
t’stat or repair
w iring
Y
Y
G as valve solenoids
check O K?
N
Y
Igniter OK? 50 to 400 ohms
N
R eplace
defective igniter
120VAC to gas valve
solenoids?
Y
R eplace gas valve
assembly
O pen wiring in
gas valve circuit,
locate & repair.
H eat selected & m otor running.
C heck for 120VAC at pin 16
on the gas valve to neutral.
Bad connection
or defective
board.
N
Y
Y
N
Flam e Detector contacts
closed?
Y
R eplace Flame
D etrector
N
No Heat - Drum Turns
Summary of Contents for Profile DPSB620