ForanswerstoyourMonogram,
®
GEProfile
™
or
GE
®
appliancequestions,visitourwebsiteat
ge.comorcallGEAnswerCenter
®
service,
800.626.2000.
PSH25MGS
GEProfileCustomStyle
™
ENERGYSTAR
®
24.6Cu.Ft.StainlessSide-By-SideRefrigerator
Specification Revised 3/06
210282
R
Listed by
Underwriters
Laboratories
R
As an EnErgy StAr
®
partner, gE has determined
that this product meets the
EnErgy StAr guidelines
for energy efficiency.
Order your own custom wood panels to match cabinetry
or other decor.
Panelsupto1/4"thickwillfitdoorframewithnospecial
preparation.Addfillerbehindmaterialthinnerthan1/4"
forproperfit.
Weight Limits:
Totalweightofpanels(i.e.,bothfreezer
panels)—FreshFood=38lbs.,Freezer=28lbs.
NOTE:
Panelsupto3/4”willrequirespecialroutingarea
aroundhandles.Dimensionsmayvarydependingon
depthofpanel.
IMPORTANT:
Beforefinalizingspecificationsforyour
GEProfileCustomStyleRefrigerator,pleaseNOTE:
•Aminimumof36-1/8"isrequiredforrefrigerator
installationwithcollar
•Besuretoallowfor1/2"or3/4"sidepanelsinaddition
tothe36-1/8"minimum.
Door Panel Dimensions and Installation Information (in inches)
Installation of Water Outlets
(FreshFoodpanelshown)
Notchrequiredattop
cornerasnoted.
Detail C
Freezer Panel
Without Dispenser
Freezer Panel
With Dispenser
Fresh Food
Panel
Cut
out
1/8
1/8
14-15/32
14-15/32
14-15/32
36-1/4
17
19-15/32
5/16
Cut
out
Cut
out
1/8
5/16
5/16
FRONT
69
69
FRONT
FRONT
Alternate
water
line location
through floor
1/2"
Water hook-up
on the refrigerator
Recommended water line
location using recess
in rear wall
Recommended
single loop of 1/4" copper water line
Water hook-up
on the refrigerator
Rear Wall View
18"
24"
Allow 48" minimum water
line to enable refrigerator
to be pulled forward
Alternate
water
line location
through floor
1/2"
Recommended water line
location using recess
in rear wall
Recommended single loop
of 1/4" copper water line
Water hook-up
on the refrigerator
Rear Wall View
Top View
Top View
18"
24"
Allow 48" minimum water
line to enable refrigerator
to be pulled forward
In.of water & Electric Ot. Art
Alternate
water
line location
through floor
1/2"
Water hook-up
on the refrigerator
Recommended water line
location using recess
in rear wall
Recommended
single loop of 1/4" copper water line
Water hook-up
on the refrigerator
Rear Wall View
18"
24"
Allow 48" minimum water
line to enable refrigerator
to be pulled forward
Alternate
water
line location
through floor
1/2"
Recommended water line
location using recess
in rear wall
Recommended single loop
of 1/4" copper water line
Water hook-up
on the refrigerator
Rear Wall View
Top View
Top View
18"
24"
Allow 48" minimum water
line to enable refrigerator
to be pulled forward
In.of water & Electric Ot. Art
5/16"
1/8"
Dr. Panel Dim. Detail C
1/4" Max.
Panels 1/4" thick
or less